SLVUDT7 April 2026
This section presents the switching waveforms under load transient condition. Here, the load current step change is between 2% and 100%, at 25Hz rate at 2.5A/µs.
Ch1 – Output Voltage (AC Coupled), Ch2 – Output Current.
Figure 3-52 Load Transient Response at VOUT =
24V Overshoot / Undershoot = 205mV / –472mV
Figure 3-54 Transient Response at VOUT = 15V
Overshoot / Undershoot = 294mV / –477mV
Figure 3-56 Transient Response at VOUT = 9V
Overshoot / Undershoot = 299mV / –449mV
Figure 3-53 Transient Response at VOUT = 20V
Overshoot / Undershoot = 289mV / –504mV
Figure 3-55 Transient Response at VOUT = 12V
Overshoot / Undershoot = 221mV / –454mV
Figure 3-57 Transient Response at VOUT = 5V
Overshoot / Undershoot = 307mV / –395mV