SLUUBT4B June   2018  – June 2025 BQ40Z80

 

  1.   1
  2.   Description
  3.   Features
  4.   4
  5. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Ordering Information
    4. 1.4 BQ40Z80 and BQ771807 Circuit Module Performance Specification Summary
  6. 2Hardware
    1. 2.1 BQ40Z80EVM Quick Start Guide
      1. 2.1.1 Items Needed for EVM Setup and Evaluation
      2. 2.1.2 Software Installation
      3. 2.1.3 EVM Connections
      4. 2.1.4 Update Firmware
    2. 2.2 Battery Management Studio
      1. 2.2.1 Registers Screen
      2. 2.2.2 Setting Programmable bq40z80 Options
      3. 2.2.3 Calibration Screen
        1. 2.2.3.1 Voltage Calibration
        2. 2.2.3.2 Temperature Calibration
        3. 2.2.3.3 Current Calibration
      4. 2.2.4 Chemistry Screen
      5. 2.2.5 Firmware Screen
        1. 2.2.5.1 Programming the Flash Memory
        2. 2.2.5.2 Exporting the Flash Memory
      6. 2.2.6 Advanced Comm SMB Screen
  7. 3Hardware Design Files
    1. 3.1 bq40z80EVM Circuit Module Schematic
      1. 3.1.1 Precharge
      2. 3.1.2 Predischarge
      3. 3.1.3 LED Control
      4. 3.1.4 Emergency Shutdown
      5. 3.1.5 Testing Fuse-Blowing Circuit
    2. 3.2 Circuit Module Physical Layouts
      1. 3.2.1 Board Layout
      2. 3.2.2 bq40z80RevA Schematic
    3. 3.3 bq40z80EVM Bill of Materials
  8. 4Additional Information
    1. 4.1 Trademarks
  9. 5Related Documentation from Texas Instruments
  10. 6Revision History

Voltage Calibration

  • Measure the voltage from 1P to 1N (VSS) and enter this value in the Applied Cell 1 Voltage field and select the Calibrate Voltage box.
  • Measure the voltage from 6P to 1N (VSS) and enter this value in the Applied Battery Voltage field and select the Calibrate Battery Voltage box.
  • Measure the voltage from Pack+ to Pack– and enter this value in the Applied Pack Voltage field and select the Calibrate Pack Voltage box. If the voltage is not present, then turn the charge and discharge FETs on by entering a 0x0022 command in the Manufacturer Access register on the Register screen.
  • If the device is configured for 7S, measure the voltage from 7P to 1N (VSS) and enter this value in the Applied Cell-7 Positive Terminal Voltage field and select the Calibrate Battery Voltage box.
  • Press the Calibrate Gas Gauge button to calibrate the voltage measurement system.
  • Deselect the Calibrate Voltage boxes after voltage calibration has completed.