ZHCSTR3B December   2010  – November 2023 TPS53315

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1  D-CAP™ Integrated Circuit with Adaptive On-Time
      2. 6.3.2  Small Signal Model
      3. 6.3.3  Ramp Signal
      4. 6.3.4  Auto-Skip Eco-mode Light Load Operation
      5. 6.3.5  Adaptive Zero Crossing
      6. 6.3.6  Forced Continuous Conduction Mode
      7. 6.3.7  Power Good
      8. 6.3.8  Current Sense and Overcurrent Protection
      9. 6.3.9  Overvoltage and Undervoltage Protection
      10. 6.3.10 UVLO Protection
      11. 6.3.11 Thermal Shutdown
    4. 6.4 Device Functional Modes
      1. 6.4.1 Enable and Soft Start
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Typical Application Circuit Diagram
        1. 7.2.1.1 Design Requirements
        2. 7.2.1.2 Detailed Design Procedure
          1. 7.2.1.2.1 Step 1: Select Operation Mode and Soft-Start Time
          2. 7.2.1.2.2 Step 2: Select Switching Frequency
          3. 7.2.1.2.3 Step 3: Select the Inductance
          4. 7.2.1.2.4 Step 4: Select Output Capacitors
          5. 7.2.1.2.5 Step 5: Determine the Voltage-Divider Resistance (R1 and R2)
          6. 7.2.1.2.6 Step 6: Select the Overcurrent Resistance (RTRIP)
        3. 7.2.1.3 Application Curves
      2. 7.2.2 Typical Application Circuit Diagram With Ceramic Output Capacitors
        1. 7.2.2.1 Design Requirements
        2. 7.2.2.2 Detailed Design Procedure
          1. 7.2.2.2.1 Step 1: Select Operation Mode and Soft-Start Time
          2. 7.2.2.2.2 Step 2: Select Switching Frequency
          3. 7.2.2.2.3 Step 3: Select the Inductance
          4. 7.2.2.2.4 Step 4: Select Output Capacitance for Ceramic Capacitors
          5. 7.2.2.2.5 Step 5: Select the Overcurrent Setting Resistance (RTRIP)
        3. 7.2.2.3 External Component Selection When Using All Ceramic Output Capacitors
        4. 7.2.2.4 Application Curves
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
        1. 7.4.2.1 Thermal Considerations
  9. Device and Documentation Support
    1. 8.1 接收文档更新通知
    2. 8.2 支持资源
    3. 8.3 Trademarks
    4. 8.4 静电放电警告
    5. 8.5 术语表
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Overvoltage and Undervoltage Protection

The TPS53315 monitors a resistor divided feedback voltage to detect overvoltage and undervoltage. When the feedback voltage becomes lower than 70% of the target voltage, the UVP comparator output goes high and an internal UVP delay counter begins counting. After 1 ms, TPS53315 latches OFF both high-side and low-side MOSFETs drivers. The controller restarts after a hiccup delay (16 ms with 0.7-ms soft-start). This function is enabled 1.5 ms after the soft-start is completed.

When the feedback voltage becomes higher than 120% of the target voltage, the OVP comparator output goes high and the circuit latches OFF the high-side MOSFET driver and latches ON the low-side MOSFET driver. The output voltage decreases. If the output voltage reaches the UV threshold, then both high-side MOSFET and low-side MOSFET driver is OFF and the device restarts after a hiccup delay. If the OV condition remains, both high-side MOSFET and low-side MOSFET driver remains OFF until the OV condition is removed.