ZHCSQ17A June   2022  – December 2022 TPS22995H-Q1

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics (VBIAS = 5 V)
    6. 6.6 Electrical Characteristics (VBIAS = 3.3 V)
    7. 6.7 Electrical Characteristics (VBIAS = 1.5 V)
    8. 6.8 Switching Characteristics
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 ON and OFF Control
      2. 8.3.2 Quick Output Discharge (QOD)
      3. 8.3.3 Adjustable Slew Rate
      4. 8.3.4 Thermal Shutdown
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  10. 10Device and Documentation Support
    1. 10.1 接收文档更新通知
    2. 10.2 支持资源
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • DDC|6
散热焊盘机械数据 (封装 | 引脚)
订购信息

Application Information

The input to output voltage drop in the device is determined by the RON of the device and the load current. The RON of the device depends upon the VIN and VBIAS condition of the device. See the RON specification in the Electrical Characteristics (VBIAS = 5 V) table of this data sheet. After the RON of the device is determined based upon the VIN and VBIAS conditions, use the below equation to calculate the input to output voltage drop.

Equation 1. GUID-D403B3BB-FBAB-434B-B38D-B554C807124F-low.gif

where

  • ΔV is the voltage drop from VIN to VOUT.
  • ILOAD is the load current.
  • RON is the on-resistance of the device for a specific VIN and VBIAS.
  • An appropriate ILOAD must be chosen such that the IMAX specification of the device is not violated.