ZHCSLU2B December   2021  – October 2023 LM63460-Q1

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Device Comparison Table
  7. Pin Configuration and Functions
    1. 6.1 Wettable Flanks
    2. 6.2 Pinout Design for Clearance and FMEA
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Characteristics
    7. 7.7 Systems Characteristics
    8. 7.8 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Input Voltage Range (VIN1, VIN2)
      2. 8.3.2  Output Voltage Setpoint (FB)
      3. 8.3.3  Precision Enable and Input Voltage UVLO (EN/SYNC)
      4. 8.3.4  Frequency Synchronization (EN/SYNC)
      5. 8.3.5  Clock Locking
      6. 8.3.6  Adjustable Switching Frequency (RT)
      7. 8.3.7  Power-Good Monitor (PGOOD)
      8. 8.3.8  Bias Supply Regulator (VCC, BIAS)
      9. 8.3.9  Bootstrap Voltage and UVLO (CBOOT)
      10. 8.3.10 Spread Spectrum
      11. 8.3.11 Soft Start and Recovery From Dropout
      12. 8.3.12 Overcurrent and Short-Circuit Protection
      13. 8.3.13 Thermal Shutdown
      14. 8.3.14 Input Supply Current
    4. 8.4 Device Functional Modes
      1. 8.4.1 Shutdown Mode
      2. 8.4.2 Standby Mode
      3. 8.4.3 Active Mode
        1. 8.4.3.1 CCM Mode
        2. 8.4.3.2 AUTO Mode – Light-Load Operation
          1. 8.4.3.2.1 Diode Emulation
          2. 8.4.3.2.2 Frequency Foldback
        3. 8.4.3.3 FPWM Mode – Light-Load Operation
        4. 8.4.3.4 Minimum On-Time (High Input Voltage) Operation
        5. 8.4.3.5 Dropout
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Design 1 – Automotive Synchronous Buck Regulator at 2.1 MHz
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1  Custom Design With WEBENCH® Tools
          2. 9.2.1.2.2  Setting the Output Voltage
          3. 9.2.1.2.3  Choosing the Switching Frequency
          4. 9.2.1.2.4  Inductor Selection
          5. 9.2.1.2.5  Output Capacitor Selection
          6. 9.2.1.2.6  Input Capacitor Selection
          7. 9.2.1.2.7  Bootstrap Capacitor
          8. 9.2.1.2.8  VCC Capacitor
          9. 9.2.1.2.9  BIAS Power Connection
          10. 9.2.1.2.10 Feedforward Network
          11. 9.2.1.2.11 Input Voltage UVLO
        3. 9.2.1.3 Application Curves
      2. 9.2.2 Design 2 – Automotive Synchronous Buck Regulator at 400 kHz
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
        3. 9.2.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
        1. 9.4.1.1 Thermal Design and Layout
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Device Support
      1. 10.1.1 第三方产品免责声明
      2. 10.1.2 Development Support
        1. 10.1.2.1 Custom Design With WEBENCH® Tools
    2. 10.2 Documentation Support
      1. 10.2.1 Related Documentation
    3. 10.3 接收文档更新通知
    4. 10.4 支持资源
    5. 10.5 Trademarks
    6. 10.6 静电放电警告
    7. 10.7 术语表
  12. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Active Mode

The converter is in active mode whenever the EN/SYNC voltage is above its threshold voltage, VIN, is high enough to satisfy VIN_OPERATE, and no other fault conditions are present. The simplest way to enable operation is to connect EN/SYNC to VIN, which allows self start-up when the applied input voltage exceeds the minimum VIN_OPERATE.

In active mode, depending on the load current, input voltage, and output voltage, the converter is in one of five modes:

  • Continuous conduction mode (CCM) with fixed switching frequency when the load current is above half of the inductor current ripple.
  • AUTO mode – Light-load operation with PFM where the switching frequency decreases at very light load.
  • FPWM mode – Light-load operation that maintains constant switching frequency across the full load range.
  • Minimum on time: The switching frequency reduces to maintain regulation with high step-down conversion ratios, that is, high input voltage to low output voltage.
  • Dropout mode: The switching frequency reduces to minimize the dropout voltage.