ZHCS766A February   2012  – December 2021 INA230

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Related Products
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements (I2C)
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Basic ADC Functions
      2. 8.3.2 Power Calculation
      3. 8.3.3 Alert Pin
    4. 8.4 Device Functional Modes
      1. 8.4.1 Averaging and Conversion Time Considerations
      2. 8.4.2 Filtering and Input Considerations
    5. 8.5 Programming
      1. 8.5.1 Programming the Calibration Register
      2. 8.5.2 Programming the INA230 Power Measurement Engine
        1. 8.5.2.1 Calibration Register and Scaling
      3. 8.5.3 Simple Current Shunt Monitor Usage (No Programming Necessary)
      4. 8.5.4 Default INA230 Settings
      5. 8.5.5 Bus Overview
        1. 8.5.5.1 Serial Bus Address
        2. 8.5.5.2 Serial Interface
      6. 8.5.6 Writing to and Reading From the I2C Serial Interface
        1. 8.5.6.1 High-Speed I2C Mode
      7. 8.5.7 SMBus Alert Response
    6. 8.6 Register Maps
      1. 8.6.1 Configuration Register (00h, Read/Write)
      2. 8.6.2 AVG Bit Settings [11:9]
      3. 8.6.3 VBUS CT Bit Settings [8:6]
      4. 8.6.4 VSH CT Bit Settings [5:3]
      5. 8.6.5 Mode Settings [2:0]
      6. 8.6.6 Data Output Register
        1. 8.6.6.1 Shunt Voltage Register (01h, Read-Only)
        2. 8.6.6.2 Bus Voltage Register (02h, Read-Only) (1)
        3. 8.6.6.3 Power Register (03h, Read-Only)
        4. 8.6.6.4 Current Register (04h, Read-Only)
        5. 8.6.6.5 Calibration Register (05h, Read/Write)
        6. 8.6.6.6 Mask/Enable Register (06h, Read/Write)
        7. 8.6.6.7 Alert Limit Register (07h, Read/Write)
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 High-Side Sensing Circuit Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 接收文档更新通知
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 术语表
  13. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Power Register (03h, Read-Only)

If averaging is enabled, this register displays the averaged value.

Table 8-11 Power Register (03h, Read-Only) Description
BIT #D15D14D13D12D11D10D9D8D7D6D5D4D3D2D1D0
BIT
NAME
PD15PD14PD13PD12PD11PD10PD9PD8PD7PD6PD5PD4PD3PD2PD1PD0
POR VALUE0000000000000000

The Power register LSB is internally programmed to equal 25 times the programmed value of the Current_LSB.

The Power register records power in watts by multiplying the decimal values of the current register with the decimal value of the bus voltage register according to Equation 4.