Check the cell specification and system requirement to determine OV and UV levels.
Define the sense resistor value and system requirement to determine OCC, OCD,
and SCD levels. For example, with a 1mΩ sense resistor and OCC, OCD, and SCD,
the requirement is 6A, 8A, and 20A, respectively. The OCC threshold should be
set to 6mV, the OCD threshold should be at 8mV, and the SCD threshold should be
at 20mV.
Determine the required OT protection threshold. The OT fault turns off the CHG and the DSG, so the threshold must account for the highest allowable charge and discharge temperature range.
When a decision is made on the various thresholds, search for whether a device configuration is available or contact the local sales office for more information.