SBOK111 June 2025 SN55LVTA4-SEP
The SN55LVTA4-SEP samples were irradiated at a high dose rate of 169.21rad(Si)/s up to 30krad(Si) and then put through full electrical parametric testing on the production Automated Test Equipment (ATE). Additionally, other SN55LVTA4-SEP samples were irradiated at a low dose rate of 8.21mrad(Si)/s up to 30krad(Si) and then put through full electrical parametric testing on the production Automated Test Equipment (ATE). The samples were functional and passed all electrical parametric tests with readings within data sheet electrical specification limits.