ZHCS429J March 2012 – November 2021 UCD3138
PRODUCTION DATA
As shown in Figure 12-2, if a current amplifier is used for current sensing, a differential input is recommended to suppress common mode noise. Then it is followed by a local low-pass filter (LPF), LPF should be placed close to the EAP and EAN pins of the UCD device. Both filters must be connected to the same ground plane (SGND).
Figure 12-2 Current
Amplifier Connected With EADC