ZHCSSH5 august   2023 LOG200

ADVANCE INFORMATION  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 High Speed, Logarithmic Current-to-Voltage Conversion
      2. 7.3.2 Voltage and Current References
      3. 7.3.3 Adaptive Photodiode Bias
      4. 7.3.4 Auxiliary Operational Amplifier
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Logarithmic Transfer Function
        1. 8.1.1.1 Logarithmic Conformity Error
    2. 8.2 Typical Application
      1. 8.2.1 Optical Current Sensing
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
        3. 8.2.1.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 第三方产品免责声明
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 接收文档更新通知
    4. 9.4 支持资源
    5. 9.5 Trademarks
    6. 9.6 静电放电警告
    7. 9.7 术语表
  11. 10Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)
MIN MAX UNIT
VS Supply voltage, VS = (VS+) – (VS–) –0.3 13 V
I1 or I2 to VCM –5.5 5.5 V
I1, I2, and VCM Voltage (VS–) – 0.3 (VS+) + 0.3 V
Current 20 mA
Auxiliary amplifier input voltage Single-ended (VS–) – 0.3 (VS+) + 0.3 V
Differential (V+IN) – (V–IN) –0.3 0.3
Auxiliary amplifier input current –10 10 mA
Output short-circuit (2) Continuous mA
Operating temperature –40 125
TJ Junction temperature –55 150
Tstg Storage temperature, Tstg –60 160
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
Short-circuit to ground, one amplifier per package.