ZHCSM38 december   2020 DAC43701 , DAC53701

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics
    6. 7.6  Timing Requirements: I2C Standard Mode
    7. 7.7  Timing Requirements: I2C Fast Mode
    8. 7.8  Timing Requirements: I2C Fast Mode Plus
    9. 7.9  Timing Requirements: GPI
    10. 7.10 Timing Diagram
    11. 7.11 Typical Characteristics: VDD = 5.5 V (Reference = VDD) or VDD = 5 V (Internal Reference)
    12. 7.12 Typical Characteristics: VDD = 1.8 V (Reference = VDD) or VDD = 2 V (Internal Reference)
    13. 7.13 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Digital-to-Analog Converter (DAC) Architecture
        1. 8.3.1.1 Reference Selection and DAC Transfer Function
          1. 8.3.1.1.1 Power Supply as Reference
          2. 8.3.1.1.2 Internal Reference
      2. 8.3.2 General-Purpose Input (GPI)
      3. 8.3.3 DAC Update
        1. 8.3.3.1 DAC Update Busy
      4. 8.3.4 Nonvolatile Memory (EEPROM or NVM)
        1. 8.3.4.1 NVM Cyclic Redundancy Check
        2. 8.3.4.2 NVM_CRC_ALARM_USER Bit
        3. 8.3.4.3 NVM_CRC_ALARM_INTERNAL Bit
      5. 8.3.5 Programmable Slew Rate
      6. 8.3.6 Power-on-Reset (POR)
      7. 8.3.7 Software Reset
      8. 8.3.8 Device Lock Feature
      9. 8.3.9 PMBus Compatibility
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power Down Mode
      2. 8.4.2 Continuous Waveform Generation (CWG) Mode
      3. 8.4.3 PMBus Compatibility Mode
      4. 8.4.4 Medical Alarm Generation Mode
        1. 8.4.4.1 Low-Priority Alarm
        2. 8.4.4.2 Medium-Priority Alarm
        3. 8.4.4.3 High-Priority Alarm
        4. 8.4.4.4 Interburst Time
        5. 8.4.4.5 Pulse Off Time
        6. 8.4.4.6 Pulse On Time
    5. 8.5 Programming
      1. 8.5.1 F/S Mode Protocol
      2. 8.5.2 I2C Update Sequence
        1. 8.5.2.1 Address Byte
          1. 8.5.2.1.1 Slave Address Configuration
        2. 8.5.2.2 Command Byte
      3. 8.5.3 I2C Read Sequence
    6. 8.6 Register Map
      1. 8.6.1  STATUS Register (address = D0h) [reset = 000Ch or 0014h]
      2. 8.6.2  GENERAL_CONFIG Register (address = D1h) [reset = 01F0h]
      3. 8.6.3  CONFIG2 Register (address = D2h) [reset = 0000h]
      4. 8.6.4  TRIGGER Register (address = D3h) [reset = 0008h]
      5. 8.6.5  DAC_DATA Register (address = 21h) [reset = 0000h]
      6. 8.6.6  DAC_MARGIN_HIGH Register (address = 25h) [reset = 0000h]
      7. 8.6.7  DAC_MARGIN_LOW Register (address = 26h) [reset = 0000h]
      8. 8.6.8  PMBUS_OPERATION Register (address = 01h) [reset = 0000h]
      9. 8.6.9  PMBUS_STATUS_BYTE Register (address = 78h) [reset = 0000h]
      10. 8.6.10 PMBUS_VERSION Register (address = 98h) [reset = 2200h]
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Appliance Light Fade-In Fade-Out
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curves
      2. 9.2.2 Power-Supply Margining
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
        3. 9.2.2.3 Application Curves
      3. 9.2.3 Medical Alarm Generation
        1. 9.2.3.1 Design Requirements
        2. 9.2.3.2 Detailed Design Procedure
        3. 9.2.3.3 Application Curves
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 接收文档更新通知
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 静电放电警告
    6. 12.6 术语表
  14. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

PMBus Compatibility Mode

The DACx3701 I2C interface implements some of the PMBus commands. Table 8-7 shows the supported PMBus commands that are implemented in DACx3701.The DAC uses MARGIN_LOW (address 26h), MARGIN_HIGH (address 25h) bits, SLEW_RATE, and CODE_STEP bits (address D1h) for PMBUS_OPERATION_CMD. The EN_PMBUS bit (Bit 12, address D1h) must be set to 1 to enable the PMBus protocol.

Table 8-7 PMBus Operation Commands
REGISTER ADDRESS AND NAMEPMBUS_OPERATION_CMD[15:8]DESCRIPTION
01h, PMBUS_OPERATION00hTurn off
80hTurn on
94hMargin low
A4hMargin high

The DACx3701 also implement PMBus features such as group command protocol and communication time-out failure. The CML bit (address 78h) indicates a communication fault in the PMBus. This bit is reset by writing 1.

To get the PMBus version, read the PMBUS_VERSION bits (address 98h).