SLOK022 December   2024 TLV4H290-SEP

 

  1.   1
  2. 1TLV4H290-SEP Radiation Tolerant High-Speed Comparator TID Report
  3. 2Trademarks
  4. 3Device Information
    1. 3.1 Device Details
  5. 4Total Dose Test Setup
    1. 4.1 Test Overview
    2. 4.2 Test Description and Facilities
    3. 4.3 Test Setup Details
      1. 4.3.1 Unbiased
      2. 4.3.2 Biased
    4. 4.4 Test Configuration and Condition
  6. 5Tested Parameters
  7. 6Total Ionizing Dose RHA Characterization Summary Results
    1. 6.1 HDR Characterization Results
      1. 6.1.1 Input Bias Current
      2. 6.1.2 Output High Leakage
    2. 6.2 Summary of Results
  8.   A Appendix A: Total Ionizing Dose HDR Report
  9.   B Appendix B: Total Ionizing Dose HDR Report - Post-Anneal

Biased

Figure 4-1 shows bias conditions for each pin during HDR exposure and extended room temperature annealing.

Ch1 and Ch2 are biased output high.

Ch3 and Ch4 are biased output low.

TLV4H290-SEP TLV4H390-SEP Biased DiagramFigure 4-1 TLV4H390-SEP Biased Diagram