over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| Supply voltage (IDD ≤
10mA) | | 15 | V |
| Supply current | | 20 | mA |
| OUTA/OUTB source current (peak)(2) | –0.5 | | A |
| OUTA/OUTB sink current (peak)(2) | | 1 | A |
| Analog inputs (FB, CS) – 0.3V
to VDD + 0.3V | | 6 | V |
| Power dissipation at T A =
25°C (D Package) | | 650 | mW |
| TJ | Junction temperature | –55 | 150 | °C |
| Lead temperature (soldering,
10 seconds) | | 300 | °C |
| Tstg | Storage temperature | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute Maximum Ratings do not imply functional operation of the device
at these or any other conditions beyond those listed under Recommended Operating
Conditions. If used outside the Recommended Operating Conditions but within
the Absolute Maximum Ratings, the device may not be fully functional, and this may
affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) Currents are positive into, negative out of the specified terminal. Consult the
Packaging Section of the
Power Supply Control Data Book for thermal limitations and