| MODE | UNIT | |||||
|---|---|---|---|---|---|---|
| FAST MODE | HIGH SPEED MODE | |||||
| MIN | MAX | MIN | MAX | |||
| fSCL | SCL clock frequency(1) | 1 | 3.4 | MHz | ||
| tSUSTA | START condition setup time for repeated start | 260 | 160 | ns | ||
| tHDSTA | Start condition hold time | 260 | 160 | ns | ||
| tLOW | Clock low period | 500 | 160 | ns | ||
| tHIGH | Clock high period | 260 | 60 | ns | ||
| tSUDAT | Data in setup time | 50 | 10 | ns | ||
| tHDDAT | Data in hold time | 0 | 0 | ns | ||
| tR | SCL rise time | 120 | 80 | ns | ||
| tF | SCL fall time | 120 | 80 | ns | ||
| tSUSTO | STOP condition hold time | 260 | 60 | ns | ||
| tBUF | Bus free time before new transmission | 500 | 300 | ns | ||