ZHCSKG3B September 2016 – February 2024 DS280DF810
PRODUCTION DATA
请参考 PDF 数据表获取器件具体的封装图。
Between each group of two adjacent channels (for example, between channels 0–1, 2–3, 4–5, and 6–7) is a full 2×2 cross-point switch. The cross-point can be configured through SMBus registers to operate as follows:
Figure 6-1 shows the four 2x2 cross-points available in the DS280DF810, and Figure 6-2 shows how each cross-point can be configured for straight-thru, multiplex, de-multiplex, or cross-over applications. Refer to the DS280DF810 Programming Guide for details on how to program the cross-point through SMBus registers.
Figure 6-1 Block
diagram showing all four 2x2 cross-points in the DS280DF810
Figure 6-2 Signal
distribution options available in each 2x2 cross-point (channel A can be 0, 2,
4, or 6; channel B can be 1, 3, 5, or 7)