DIAG Status C iss shown in Figure 48 and described in Table 19.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| SC_OC | SHT_GND_C | SHT_BAT_C | OL_PH_C | VGS_LC | VGS_HC | VDS_LC | VDS_HC |
| R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b |
| Bit | Field | Type | Default | Description |
|---|---|---|---|---|
| 7 | SC_OC | R | 0b |
Indicates overcurrent on Phase C sense amplifier |
| 6 | SHT_GND_C | R | 0b |
Indicates offline short-to-ground fault in Phase C |
| 5 | SHT_BAT_C | R | 0b |
Indicates offline short to battery fault in Phase C |
| 4 | OL_PH_C | R | 0b |
Indicates open load fault in Phase C |
| 3 | VGS_LC | R | 0b |
Indicates gate drive fault on the C low-side MOSFET |
| 2 | VGS_HC | R | 0b |
Indicates gate drive fault on the C high-side MOSFET |
| 1 | VDS_LC | R | 0b |
Indicates VDS overcurrent fault on the C low-side MOSFET |
| 0 | VDS_HC | R | 0b |
Indicates VDS overcurrent fault on the C high-side MOSFET |