ZHCSJ76A March 2018 – April 2019 DRV8343-Q1
PRODUCTION DATA.
FAULT Status is shown in Figure 45 and described in Table 16.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| FAULT | GDF | CPUV | UVLO | OCP | OTW | OTSD | OL_SHT |
| R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b |
| Bit | Field | Type | Default | Description |
|---|---|---|---|---|
| 7 | FAULT | R | 0b |
Logic OR of FAULT status registers |
| 6 | GDF | R | 0b |
Indicates gate drive fault condition |
| 5 | CPUV | R | 0b |
Indicates charge pump undervoltage fault condition |
| 4 | UVLO | R | 0b |
Indicates undervoltage lockout fault condition |
| 3 | OCP | R | 0b |
Indicated overcurrent fault condition either by VDS or SEN_OCP |
| 2 | OTW | R | 0b |
Indicates overtemperature warning |
| 1 | OTSD | R | 0b |
Indicates overtemperature shutdown |
| 0 | OL_SHT | R | 0b |
Indicates open load detection, or offline short-to-supply or GND detection |