ZHCSH75A September 2017 – December 2017 ADS7142
PRODUCTION DATA.
Provides the channel ID of channel which was first to set the alert output (Read Only).
This register is cleared at power-up, on receiving general call reset, on device reset or when SEQ_START bit in START_SEQUENCE register is set to 1.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| ALERT_TRIG_CHID[3:0] | 0 | 0 | 0 | 0 | |||
| R-0000b | R-0b | R-0b | R-0b | R-0b | |||
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-4 | ALERT_TRIG_CHID[3:0] | R | 0000b | Provides the channel ID of channel which was first to set the alert output
0000b = Channel 0 0001b = Channel 1 0010b to 1111b = Not used |