ZHCSKX3 March 2020 PCM6240-Q1 , PCM6260-Q1 , PCM6340-Q1 , PCM6360-Q1
ADVANCE INFORMATION for pre-production products; subject to change without notice.
This register is the live Interrupt status register for channel 6 fault diagnostic. Applicable only for PCM6x60-Q1.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH6_LIVE[7] | CH6_LIVE[6] | CH6_LIVE[5] | CH6_LIVE[4] | CH6_LIVE[3] | CH6_LIVE[2] | CH6_LIVE[1] | CH6_LIVE[0] |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | CH6_LIVE[7] | R | 0h | Channel 6 open input fault status.
0b = No open input detected 1b = Open input detected |
| 6 | CH6_LIVE[6] | R | 0h | Channel 6 input pair short fault status.
0b = No input pair short detected 1b = Input short to each other detected |
| 5 | CH6_LIVE[5] | R | 0h | Channel 6 IN6P short to ground fault status.
0b = IN6P no short to ground detected 1b = IN6P short to ground detected |
| 4 | CH6_LIVE[4] | R | 0h | Channel 6 IN6M short to ground fault status.
0b = IN6M no short to ground detected 1b = IN6M short to ground detected |
| 3 | CH6_LIVE[3] | R | 0h | Channel 6 IN6P short to MICBIAS fault status.
0b = IN6P no short to MICBIAS detected 1b = IN6P short to MICBIAS detected |
| 2 | CH6_LIVE[2] | R | 0h | Channel 6 IN6M short to MICBIAS fault status.
0b = IN6M no short to MICBIAS detected 1b = IN6M short to MICBIAS detected |
| 1 | CH6_LIVE[1] | R | 0h | Channel 6 IN6P short to VBAT_IN fault status.
0b = IN6P no short to VBAT_IN detected 1b = IN6P short to VBAT_IN detected |
| 0 | CH6_LIVE[0] | R | 0h | Channel 6 IN6M short to VBAT_IN fault status.
0b = IN6M no short to VBAT_IN detected 1b = IN6M short to VBAT_IN detected |