ZHCSKX3 March 2020 PCM6240-Q1 , PCM6260-Q1 , PCM6340-Q1 , PCM6360-Q1
ADVANCE INFORMATION for pre-production products; subject to change without notice.
This register is the live Interrupt status register for channel 5 fault diagnostic. Applicable only for PCM6x60-Q1.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH5_LIVE[7] | CH5_LIVE[6] | CH5_LIVE[5] | CH5_LIVE[4] | CH5_LIVE[3] | CH5_LIVE[2] | CH5_LIVE[1] | CH5_LIVE[0] |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | CH5_LIVE[7] | R | 0h | Channel 5 open input fault status.
0b = No open input detected 1b = Open input detected |
| 6 | CH5_LIVE[6] | R | 0h | Channel 5 input pair short fault status.
0b = No input pair short detected 1b = Input short to each other detected |
| 5 | CH5_LIVE[5] | R | 0h | Channel 5 IN5P short to ground fault status.
0b = IN5P no short to ground detected 1b = IN5P short to ground detected |
| 4 | CH5_LIVE[4] | R | 0h | Channel 5 IN5M short to ground fault status.
0b = IN5M no short to ground detected 1b = IN5M short to ground detected |
| 3 | CH5_LIVE[3] | R | 0h | Channel 5 IN5P short to MICBIAS fault status.
0b = IN5P no short to MICBIAS detected 1b = IN5P short to MICBIAS detected |
| 2 | CH5_LIVE[2] | R | 0h | Channel 5 IN5M short to MICBIAS fault status.
0b = IN5M no short to MICBIAS detected 1b = IN5M short to MICBIAS detected |
| 1 | CH5_LIVE[1] | R | 0h | Channel 5 IN5P short to VBAT_IN fault status.
0b = IN5P no short to VBAT_IN detected 1b = IN5P short to VBAT_IN detected |
| 0 | CH5_LIVE[0] | R | 0h | Channel 5 IN5M short to VBAT_IN fault status.
0b = IN5M no short to VBAT_IN detected 1b = IN5M short to VBAT_IN detected |