TIDT446A June   2025  – July 2025

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
    4. 1.4 Test Setup
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Voltage Regulation
    3. 2.3 Efficiency Data
    4. 2.4 Thermal Images
    5. 2.5 EMI
  7. 3Waveforms
    1. 3.1 AC Brown In and Brown Out
    2. 3.2 AC Start-Up and Shut-Down
    3. 3.3 Voltage Transition
    4. 3.4 Switching
    5. 3.5 Output Voltage Ripple
    6. 3.6 Load Transients
    7. 3.7 Short-Circuit Protection
    8. 3.8 Feedback Loop Open Protection

Switching

PMP41163 90VAC, 20V, 3.25A, VswFigure 3-9 90VAC, 20V, 3.25A, Vsw
PMP41163 230VAC, 20V, 3.25A, VswFigure 3-11 230VAC, 20V, 3.25A, Vsw
PMP41163 230VAC, 20V, 3.25A, 100%
                        Load, VswFigure 3-13 230VAC, 20V, 3.25A, 100% Load, Vsw
PMP41163 230VAC, 20V, 1.62A, 50%
                        Load, VswFigure 3-15 230VAC, 20V, 1.62A, 50% Load, Vsw
PMP41163 230VAC, 20V, 0.325A, 10%
                        Load, VswFigure 3-17 230VAC, 20V, 0.325A, 10% Load, Vsw
PMP41163 115VAC, 5V Open Load,
                        VswFigure 3-19 115VAC, 5V Open Load, Vsw
PMP41163 115VAC, 20V, 3.25A, VswFigure 3-10 115VAC, 20V, 3.25A, Vsw
PMP41163 264VAC, 20V, 3.25A, VswFigure 3-12 264VAC, 20V, 3.25A, Vsw
PMP41163 230VAC, 20V, 2.45A, 75%
                        Load, VswFigure 3-14 230VAC, 20V, 2.45A, 75% Load, Vsw
PMP41163 230VAC, 20V, 0.81A, 25%
                        Load, VswFigure 3-16 230VAC, 20V, 0.81A, 25% Load, Vsw
PMP41163 230VAC, 5V Open Load,
                        VswFigure 3-18 230VAC, 5V Open Load, Vsw