TIDT446A
June 2025 – July 2025
1
Description
Features
Applications
1
Test Prerequisites
1.1
Voltage and Current Requirements
1.2
Required Equipment
1.3
Dimensions
1.4
Test Setup
2
Testing and Results
2.1
Efficiency Graphs
2.2
Voltage Regulation
2.3
Efficiency Data
2.4
Thermal Images
2.5
EMI
3
Waveforms
3.1
AC Brown In and Brown Out
3.2
AC Start-Up and Shut-Down
3.3
Voltage Transition
3.4
Switching
3.5
Output Voltage Ripple
3.6
Load Transients
3.7
Short-Circuit Protection
3.8
Feedback Loop Open Protection
1.2
Required Equipment
AC source: Chroma Model 61601
Digital power meter: Yokogawa WT310
Power-Z P240 Bidirectional Multi-protocol Power Supply
DC source: GWinstek, GPS-3303C
Bidirectional power source: IT6010C-80-300
Electronic load: Chroma, 6314A
Oscilloscope: Tektronix, DPO 3054
Infrared thermal camera: Fluke, TiS55
Ture-RMS-Multimeter: Fluke, 287C