SLVK183 February   2025 TPS7H6005-SP , TPS7H6015-SP , TPS7H6025-SP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. Introduction
  5. Single-Event Effects (SEE)
  6. Device and Test Board Information
  7. Irradiation Facility and Setup
  8. Depth, Range, and LETEFF Calculation
  9. Test Setup and Procedures
  10. Destructive Single-Event Effects (DSEE)
    1. 7.1 Single-Event Latch-up (SEL) Results
    2. 7.2 Single-Event Burnout (SEB) and Single-Event Gate Rupture (SEGR) Results
  11. Single-Event Transients (SET)
  12. Event Rate Calculations
  13. 10Summary
  14.   A References

Device and Test Board Information

The TPS7H60x5-SP is packaged in a 56-pin plastic package as shown in Figure 3-1. A TPS7H60x5-SP evaluation board made specifically for radiation testing was used to evaluate the performance and characteristics of the TPS7H60x5-SP under heavy ion radiation. The TPS7H60x5-SP evaluation board is shown in Figure 3-2. The board schematic is shown in Figure 3-3.

The package was delidded to reveal the die face for all heavy-ion testing.

 Photograph of Delidded TPS7H6005-SP (Left) and Pinout Diagram (Right)Figure 3-1 Photograph of Delidded TPS7H6005-SP (Left) and Pinout Diagram (Right)
 TPS7H60x5-SP EVM Top ViewFigure 3-2 TPS7H60x5-SP EVM Top View
 TPS7H60x5-SP Evaluation Board SchematicsFigure 3-3 TPS7H60x5-SP Evaluation Board Schematics