SLVK168 February   2024 TPS7H3014-SP

PRODUCTION DATA  

  1.   1
  2.   TPS7H3014-SP Total Ionizing Dose (TID) Radiation Report
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
      1. 3.2.1 Electrical Characteristics
      2. 3.2.2 Timing Requirements
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   A Appendix: HDR TID Report Data

Test Configuration and Condition

HDR devices were stressed at 50 krad(Si) and 100 krad(Si) for biased and unbiased conditions.

Table 2-1 HDR: 50krad(Si) and 100krad(Si)/s Biased Device Information
Total Samples: 10
Exposure Levels
50krad(Si)100krad(Si)
9, 10, 11, 12, 1319, 20, 21, 22, 23
Table 2-2 HDR: 50krad(Si) and 100krad(Si)/s Unbiased Device Information
Total Samples: 10
Exposure Levels
50krad(Si)100krad(Si)
2, 3, 5, 6, 714, 15, 16, 17, 18