SLUUCM7 October   2022 TPS563300

 

  1.   TPS563300EVM-226 3-A, Regulator Evaluation Module
  2.   Trademarks
  3. 1Introduction
  4. 2Performance Specification Summary
  5. 3Modifications
    1. 3.1 Output Voltage Setpoint
  6. 4Test Setup and Results
    1. 4.1 Input and Output Connections
    2. 4.2 Start-Up Procedure
    3. 4.3 Load Transient Response
    4. 4.4 Output Voltage Ripple
    5. 4.5 Start-Up
    6. 4.6 Shutdown
  7. 5Board Layout
    1. 5.1 Layout
  8. 6Schematic and List of Materials
    1. 6.1 Schematic
    2. 6.2 List of Materials

Start-Up Procedure

  1. Ensure that the jumper at JP2 (Enable control) pins 2 and 3 are covered to shunt EN to GND, disabling the output.
  2. Apply appropriate VIN voltage to VIN (J2-1) and GND (J2-2).
  3. Move the jumper at JP2 (Enable control) pins 2 and 3 (EN and GND) to enable the output.