SBOK097B April   2025  – June 2025 TMP9R01-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1 Introduction
  5. 2 Sample Identification
  6. 3 Irradiation Facility and Setup
  7. 4 Die Micro-section
  8. 5 Test Set-Up
  9. 6 SEL Results
    1. 6.1 TMP9R01-SEP SEL Data
  10. 7 SET Results
    1. 7.1 Summary of SET Results
      1. 7.1.1 Local Temperature Reads
        1. 7.1.1.1 Analog Alert Captures
    2. 7.2 Cross Section Events and Event Rate Calculations
  11. 8 Detailed Results Per Run
    1. 8.1 Detailed Run Raw Data
  12. 9 Summary
  13. 10Glossary
  14. 11Revision History

TMP9R01-SEP SEL Data

Table 6-1 TMP9R01-SEP SEL Data

Lot #

Device / Bias

Run #

Pass/Fail

Temp (°C) Thermo Camera

Distance (mm)

Ion

Initial Energy (MeV/nucleon)

Thetha Table Angle (°)

LETEFF (MeV∙cm²/mg)

Target Flux (ions∙cm²/s)

Fluence (# of ions∙cm²)

VCM Clamp

VS (V)

VS clamp

Measured IS (mA) Before Beam

Measured IS (mA) Post Beam

Measured IS (mA) At Beam

MSU

2

3

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 3.3V

500mA

60-400uA

60-400uA

60-400uA

MSU

2

4

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 3.6V

500mA

60-400uA

60-400uA

60-400uA

MSU

2

5

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 1.7V

500mA

60-400uA

60-400uA

60-400uA

MSU

3

6

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 3.6V

500mA

60-400uA

60-400uA

60-400uA

MSU

3

7

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 3.3V

500mA

60-400uA

60-400uA

60-400uA

MSU

3

8

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1E+07

5mA

Vs1 = Vs2 = 1.7V

500mA

60-400uA

60-400uA

60-400uA

MSU

4

9

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1.5E+07

5mA

Vs1 = Vs2 = 3.6V

500mA

60-400uA

60-400uA

60-400uA

MSU

4

10

Pass

125C

70

Xe

50.4

0

50.4

1E+05

1.5E+07

5mA

Vs1 = Vs2 = 1.7V

500mA

60-400uA

60-400uA

60-400uA

 Run Passing SEL Run 4, DUT #2, MSU, 125C, Xe (50.4MeV)Figure 6-1 Run Passing SEL Run 4, DUT #2, MSU, 125C, Xe (50.4MeV)
 Run Passing SEL Run 7, DUT #3, MSU, 125C, Xe (50.4MeV)Figure 6-2 Run Passing SEL Run 7, DUT #3, MSU, 125C, Xe (50.4MeV)
 Run Passing SEL Run 9, DUT #4, MSU, 125C, Xe (50.4MeV)Figure 6-3 Run Passing SEL Run 9, DUT #4, MSU, 125C, Xe (50.4MeV)