ZHCSIE2M June 2008 – June 2018 TPS735
PRODUCTION DATA.
The device is disabled under the following conditions:
Table 1 lists the conditions that result in different modes of operation.
| OPERATING MODE | PARAMETER | |||
|---|---|---|---|---|
| VIN | VEN | IOUT | TJ | |
| Normal mode | VIN > VOUTnom + VDO and VIN > UVLO | VEN > VEN(HI) | IOUT < ILIM | TJ < 125°C |
| Dropout mode | UVLO < VIN < VOUTnom + VDO | VEN > VEN(HI) | — | TJ < 165°C |
| Disabled mode
(any true condition disables the device) |
VIN < UVLO – Vhys | VEN < VEN(LO) | — | TJ > 165°C |