ZHCSNR7A March   2022  – August 2022 TPS55289

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 I2C Timing Characteristics
    7. 6.7 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  VCC Power Supply
      2. 7.3.2  EXTVCC Power Supply
      3. 7.3.3  Operation Mode Setting
      4. 7.3.4  Input Undervoltage Lockout
      5. 7.3.5  Enable and Programmable UVLO
      6. 7.3.6  Soft Start
      7. 7.3.7  Shutdown and Load Discharge
      8. 7.3.8  Switching Frequency
      9. 7.3.9  Switching Frequency Dithering
      10. 7.3.10 Inductor Current Limit
      11. 7.3.11 Internal Charge Path
      12. 7.3.12 Output Voltage Setting
      13. 7.3.13 Output Current Monitoring and Cable Voltage Droop Compensation
      14. 7.3.14 Output Current Limit
      15. 7.3.15 Overvoltage Protection
      16. 7.3.16 Output Short Circuit Protection
      17. 7.3.17 Thermal Shutdown
    4. 7.4 Device Functional Modes
      1. 7.4.1 PWM Mode
      2. 7.4.2 Power Save Mode
    5. 7.5 Programming
      1. 7.5.1 Data Validity
      2. 7.5.2 START and STOP Conditions
      3. 7.5.3 Byte Format
      4. 7.5.4 Acknowledge (ACK) and Not Acknowledge (NACK)
      5. 7.5.5 Target Address and Data Direction Bit
      6. 7.5.6 Single Read and Write
      7. 7.5.7 Multiread and Multiwrite
    6. 7.6 Register Maps
      1. 7.6.1 REF Register (Address = 0h, 1h)
      2. 7.6.2 IOUT_LIMIT Register (Address = 2h) [reset = 11100100h]
      3. 7.6.3 VOUT_SR Register (Address = 3h) [reset = 00000001h]
      4. 7.6.4 VOUT_FS Register (Address = 4h) [reset = 00000011h]
      5. 7.6.5 CDC Register (Address = 5h) [reset = 11100000h]
      6. 7.6.6 MODE Register (Address = 6h) [reset = 00100000h]
      7. 7.6.7 STATUS Register (Address = 7h) [reset = 00000011h]
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Switching Frequency
        2. 8.2.2.2 Output Voltage Setting
        3. 8.2.2.3 Inductor Selection
        4. 8.2.2.4 Input Capacitor
        5. 8.2.2.5 Output Capacitor
        6. 8.2.2.6 Output Current Limit
        7. 8.2.2.7 Loop Stability
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 第三方产品免责声明
    2. 11.2 接收文档更新通知
    3. 11.3 支持资源
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 术语表
  12. 12Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

STATUS Register (Address = 7h) [reset = 00000011h]

STATUS is shown in Figure 7-22 and described in Table 7-11.

Return to Summary Table.

The STATUS register stores the operating status of the TPS55289. When any of the SCP bit, the OCP bit, or the OVP bit are set, and the corresponding mask bit in register 05h is set as well, the FB/INT̅ pin outputs low logic level to indicate the situation. Reading register 07h clears the SCP bit, OCP bit, and OVP bit. After the SCP bit, OCP bit, or OVP bit is set, it does not reset until the register is read. If the situation still exists, the corresponding bit is set again.

Figure 7-22 STATUS Register
76543210
SCPOCPOVPReservedReservedReservedSTATUS
R-0bR-0bR-0bR/W-0bR/W-0bR/W-0bR-11b
Table 7-11 STATUS Register Field Descriptions
BitFieldTypeResetDescription
7SCPR0bShort circuit protection

0b = No short circuit

1b = Short circuit happens. Does not reset until it is read.

6OCPR0bOvercurrent protection

0b = No output overcurrent

1b = Output current hits the current limit sensed at the ISP and the ISN pin. Does not reset until it is read.

5OVPR0bOvervoltage protection

0b = No OVP

1b = Output voltage exceeds the OVP threshold. Does not reset until it is read.

4RESERVEDR0bReserved
3RESERVEDR0bReserved
2RESERVEDR0bReserved
1-0STATUSR11bOperating status

00b = Boost

01b = Buck

10b = Buck-Boost

11b = Reserved