ZHCSVF8C January   1977  – March 2024 SN75158

PRODUCTION DATA  

  1.   1
  2. 1特性
  3. 2应用
  4. 3说明
  5. 4Pin Configuration and Functions
  6. 5Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Typical Characteristics
  7.   Parameter Measuremrnt Information
  8. 6Device and Documentation Support
    1. 6.1 接收文档更新通知
    2. 6.2 支持资源
    3. 6.3 商标
    4. 6.4 静电放电警告
    5. 6.5 术语表
  9. 7Revision History
  10. 8Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • D|8
  • P|8
  • PS|8
散热焊盘机械数据 (封装 | 引脚)
订购信息

Electrical Characteristics

over recommended ranges of supply voltage,common-mode input voltage, and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS(1) MIN TYP(2) MAX UNIT
VIK Input clamp voltage VCC = MIN, II = –12mA –0.9 –1.5 V
VOH High-level output voltage VCC = MIN,
VIH = 2V,
VIL = 0.8V,
IOH = –40mA
2.4 3 V
VOL Low-level output voltage VCC = MIN,
VIH = 2V,
VIL = 0.8V,
IOH = 40mA
0.2 0.4 V
|VOD1| Differential output voltage VCC = MAX, IO = 0 3.5 2 × VOD2 V
|VOD2| VCC = MIN, RL = 100Ω,
See Figure 6-1
3 3 V
ΔVOD Change in magnitude of differential output voltage(3) VCC = MIN, RL = 100Ω,
See Figure 6-1
±0.02 ±0.4 V
VOC Common-mode output voltage(4) VCC = MAX, RL = 100Ω,
See Figure 6-1
1.8 3 V
VCC = MIN, 1.5 3
ΔVOC Change in magnitude of common-mode output voltage(3) VCC = MIN or MAX, RL = 100Ω,
See Figure 6-1
±0.02 ±0.4 V
IO Output current with power off VCC = 0, VO = 6V 0.1 100 μA
VO = –0.25V –0.1 –100
VO = –0.25 to 6V ±100
II Input current at maximum input voltage VCC = MAX, VI = 5.5V 1 mA
IIH High-level input current VCC = MAX, VI = 2.4V 40 μA
IIL Low-level input current VCC = MAX, VI = 0.4V –1 –1.6 mA
IOS Short-circuit output current(5) VCC = MAX, –40 –90 –150 mA
ICC Supply current (both drivers) VCC = MAX,
TA = 25°C,
Inputs grounded,
No load
37 50 mA
For conditions shown as MIN or MAX, use the appropriate value specified under Recommended Operating Conditions.
All typical values are at VCC = 5 V and TA = 25°C except for VOC, for which VCC is as stated under test conditions.
ΔVOD and Δ|VOC| are the changes in magnitudes of VOD and VOC, respectively, that occur when the input is changed from a high level to a low level.
In ANSI Standard EIA/TIA-422-B, VOC, which is the average of the two output voltages with respect to ground, is called output offset voltage, VOS.
Only one output should be shorted at a time, and duration of the short circuit should not exceed one second.