To improve the switching characteristics and efficiency of a power converter design, follow the layout recommendations mentioned below:
- Position the driver as close as possible to the power FETs.
- Position the VDD – VGND, VHB − VHS and VLB − VLS (bootstrap) capacitors as close as possible to the device. HB-HS and LB-LS are domains where gate driver block sits. Hence the decoupling capacitors provide gate charge to the FET.
- Pay close attention to the HS and LS traces. These trace from the driver go directly to the source of the power FET, but must not be in the high current path of the FET drain or source current. Use kelvin connection between HS/LS and power converter SW node.
- For systems using multiple LMG1208 devices, TI recommends locating the dedicated decoupling capacitors at VDD, HB-HS and LB-LS pins for each device.
- Take care to avoid placing VDD trace close to LG, HS, LS and HG signals.
- Use wide traces for LG and HG closely following the associated LS or HS traces.
- Use at least two or more vias if the driver outputs or SW node is routed from one layer to another. For GND, the number of vias must be a consideration of the thermal pad requirements, as well as parasitic inductance.
- Avoid INL and INH (driver input) going close to the HS/LS nodes or any other high dV/dT traces that can induce significant noise into the relatively high impedance leads.
A poor layout can cause a significant drop in efficiency or system malfunction and can lead to decreased reliability of the whole system.