3.3
Load Transients
Load step response from 5A to 20A to 5A results in a V
OUT
deviation of 3.02V
PP
.
CH1: AC-coupled output voltage [scale: 500mV/div, 2ms/div, 20MHz bandwidth]
CH4: Output current [scale: 5A/div, 2ms/div]
Figure 3-4