SPRZ491E December 2020 – December 2024 DRA821U , DRA821U-Q1
I3C: Command fetched during pending IBI is not properly processed in some cases
Writing command by host during target-initiated IBI address byte reception may lead to improper command execution by controller, including incorrect frame generation.