• Menu
  • Product
  • Email
  • PDF
  • Order now
  • Jacinto Functional Safety Enablers

    • SPRB209A August   2022  – December 2022 DRA821U , DRA821U-Q1 , DRA829J , DRA829J-Q1 , DRA829V , DRA829V-Q1 , TDA4VM , TDA4VM-Q1

       

  • CONTENTS
  • SEARCH
  • Jacinto Functional Safety Enablers
  1.   Abstract
  2.   2
  3.   Revision History
  4. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

FUNCTIONAL SAFETY MANUAL

Jacinto Functional Safety Enablers

Abstract

Leverage our functional safety diagnostic software library, compiler qualification kits, third party operating systems & development tools, and additional functional safety documentation to help your system-level certification efforts.

Leverage our functional safety diagnostic software library, compiler qualification kits, third party operating systems and development tools, and additional functional safety documentation to help your system-level certification efforts.

Table 1 Jacinto Functional Safety Enablers
Functional Safety Assessments Products Descriptions Access
TUV-SUD certificate for QRAS-AP00210

TDA4VM

DRA829

DRA821

Functional safety development process for IEC 61508 and ISO 26262 Compliant Hardware Components Download
TUV-SUD certificate for QRAS-AP00216

TDA4VM

DRA829

DRA821

Functional safety development process for IEC 61508 and ISO 26262 Compliant Software Development Download

Device Safety Assessment Certificate

TDA4VM

DRA829

(Automotive)

SoC meets ISO 26262 standards to achieve up to ASIL-D. Download

TDA4VM

DRA829

(Industrial)

SoC meets IEC 61508 standards to achieve up to SIL-3 Download
DRA821 SoC meets ISO 26262 and IEC 61508 standards to achieve up to ASIL-D/SIL-3. In Progress

Device Safety Assessment Certificate

(Report on Safety Certificate)

TDA4VM

DRA829

(Automotive)

SoC meets ISO 26262 standards to achieve up to ASIL-D. Download

TDA4VM

DRA829

(Industrial)

SoC meets IEC 61508 standards to achieve up to SIL-3 Download
Jacinto Family Safety Collateral

Access

(NDA Is Required)

Device Safety Assessment Technical Report

TDA4VM

DRA829

SoC meets ISO 26262 and IEC 61508 standards to achieve up to ASIL-D/SIL-3. Request
Safety Manual

TDA4VM

DRA829

(Automotive)

Provides information to aid customers in designing systems in compliance with ISO 26262 functional safety standards

Request

TDA4VM

DRA829

(Industrial)

Provides information to aid customers in designing systems in compliance with IEC 61508 functional safety standards Request

DRA821

(Prelim. Draft)

Provides information to aid customers in designing systems in compliance with ISO 26262/ IEC61508 functional safety standards Request
FMEDA

TDA4VM

DRA829

(Automotive)

Detailed, tunable, quantitative FMEDA for Jacinto functional safety Automotive products

Request

TDA4VM

DRA829

(Industrial)

Detailed, tunable, quantitative FMEDA for Jacinto functional safety Industrial products Request

DRA821

(Prelim. Draft)

Detailed, tunable, quantitative FMEDA for Jacinto functional safety products Request
Safety Analysis Report

TDA4VM

DRA829

(Automotive)

Summary of FIT rates, diagnostic coverage, and assumptions at the device level Jacinto functional safety Automotive products

Request

TDA4VM

DRA829

(Industrial)

Summary of FIT rates, diagnostic coverage, and assumptions at the device level Jacinto functional safety Industrial products Request

DRA821

(Prelim. Draft)

Summary of FIT rates, diagnostic coverage, and assumptions at the device level Jacinto functional safety products Request
Safety Manual and FMEDA Training Jacinto Processors Video walk through on utilizing Safety Manual and FMEDA to implement functional safety concept for automotive and industrial products In Progress
HW Safety User Guide

TDA4VM

DRA829

High-level description of device safety capability, assumptions of use, safety collaterals and support and tailoring to aid customers use the SoC in designing systems Request
Functional Safety Software
Functional Safety Diagnostic Software Library (SDL)

TDA4VM

DRA829

Safety Diagnostic Software Library with Compliance Support Package Download
Safety Compiler Qualification Kit

TDA4VM

DRA829

Developed to assist customers in qualifying their use of the TI ARM, C6000, C7000 or C2000/CLA C/C++ Compiler to functional safety standards IEC 61508 and ISO 26262. Download
Functional Safety Autosar MCAL

TDA4VM

DRA829

DRA821

Autosar MCAL drivers with compliance support package In Progress
TI Safety Driver CSP

TDA4VM

DRA829

DRA821

Software modules with Compliance Support Package with User Guide In Progress
Third Party Support
SafeRTOS Jacinto Processors Safety certified Real Time Operating System (RTOS) for embedded processors Visit
AutoSAR - KPIT Jacinto Processors AUTOSAR basic software developed according to ISO 26262. Visit
AutoSAR – Vector Jacinto Processors AUTOSAR basic software developed according to ISO 26262. Visit
QNX OS for Safety – BlackBerry QNX Jacinto Processors An embedded OS pre-certified for IEC 61508 SIL3, ISO 26262 ASIL D and IEC 62304 Class C. Visit
Additional Resources
White Papers and Application Notes Jacinto Processors Streamlining Functional Safety Certification in Automotive and Industrial Download
White Papers and Application Notes Jacinto Processors Leverage Jacinto™ 7 Processors Functional Safety Features for Automotive Designs Download
White Papers and Application Notes Jacinto and Sitara Processors Optimizing Functional Safety for Industrial Robots Download
White Papers and Application Notes Jacinto Processors PMIC User Guide for TDA4VM/ DRA829 Download
Safety Concept TDA4VM

TUV certified safety concept document for collision avoidance in AMR and Last Mile delivery Robot using TDA4VM.

In Progress

Revision History

Changes from August 1, 2022 to December 31, 2022 (from Revision * (August 2022) to Revision A (December 2022))

  • Updated Jacinto Functional Safety Enablers table.Go

IMPORTANT NOTICE AND DISCLAIMER

TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS.

These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources.

TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 

Copyright © 2022, Texas Instruments Incorporated

 

Texas Instruments

© Copyright 1995-2025 Texas Instruments Incorporated. All rights reserved.
Submit documentation feedback | IMPORTANT NOTICE | Trademarks | Privacy policy | Cookie policy | Terms of use | Terms of sale