SNOA993A June   2018  – July 2021 LDC2112 , LDC2114 , LDC3114 , LDC3114-Q1

 

  1.   Trademarks
  2. 1Introduction
  3. 2Scan Rate and Sampling Interval
    1. 2.1 Low Power Mode and Normal Power Mode
    2. 2.2 Button Sequencing and Error Handling
  4. 3Data Polarity and Timeout
    1. 3.1 Button Timeout
  5. 4Internal Algorithms Overview
  6. 5Baseline Tracking
    1. 5.1 Baseline Increment
    2. 5.2 Baseline Tracking Reset
    3. 5.3 Button Actuation Time
    4. 5.4 BTPAUSE
    5. 5.5 Fast Tracking Factor
  7. 6Gain, Hysteresis, and Threshold
    1. 6.1 Threshold and Hysteresis
  8. 7Multi-Button Algorithms
    1. 7.1 Max Win
    2. 7.2 Anti-Common Mode
    3. 7.3 Anti-Twist Factor
    4. 7.4 Anti-Deform Factor
  9. 8Summary
  10. 9Revision History

Button Timeout

The maximum supported continuous button actuation is ~50 seconds. If the button is asserted for a longer time interval, the device internal state machine automatically resets operation and the baseline tracking value automatically resets, which deasserts the button. When a timeout occurs, the device will flag the event by setting STATUS:TIMEOUT to 1.

For the LDC3114, the baseline tracking algorithm may be disabled by using the device in raw data access mode.