SNIK006A April   2025  – June 2025

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. Introduction
  5. Sample Identification
  6. Irradiation Facility and Setup
  7. Die Micro-section
  8. Test Set-Up
  9. SEL Results
    1. 6.1 TMP9R01-SP SEL Data
  10. SET Results
    1. 7.1 Summary of SET Results
      1. 7.1.1 Summary of SET Results Continued
    2. 7.2 Cross Section Events and Event Rate Calculations
  11. Detailed Results Per Run
    1. 8.1 Detailed Run Raw Data
  12. Summary
  13. 10Glossary
  14. 11Revision History

Summary of SET Results Continued

 TMP9R01 Temperature Reads
                    During 75MeV Exposure Figure 7-5 TMP9R01 Temperature Reads During 75MeV Exposure
 TMP9R01 Temperature Reads
                    During 75MeV Exposure Figure 7-6 TMP9R01 Temperature Reads During 75MeV Exposure

Scope shots of the alert signal was captured during the exposure. There where 4 common transient captures. The following captures shown below was captured with no resets to highlight to worse case with the alert signal.

 Possible Alert Signal Trip
                    During Exposure Figure 7-7 Possible Alert Signal Trip During Exposure
 Possible Alert Signal Trip
                    During Exposure Figure 7-8 Possible Alert Signal Trip During Exposure
 Possible Alert Signal Trip
                    During Exposure Figure 7-9 Possible Alert Signal Trip During Exposure
 Possible Alert Signal Trip
                    During Exposure Figure 7-10 Possible Alert Signal Trip During Exposure