SLVT221 June   2025

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Dimensions
  7. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
    4. 2.4 Bode Plots
  8. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transients
    4. 3.4 Start-up and Shutdown Sequence
  9.   Trademarks

Start-up and Shutdown Sequence

Figure 3-5 displays the start-up waveform at 48Vin input into a no load. The total rise time is 3.4ms, insinuating total start-up totaling about 4.25ms.

Figure 3-8 displays the shutdown waveform at 48Vin input into a ⅓Ω constant-resistance load using an electronic load. The total fall time is 37.2ms, insinuating total shutdown totaling about 46.4ms.

PMP23611 Start-upFigure 3-7 Start-up
PMP23611 ShutdownFigure 3-8 Shutdown