ZHCSL26C April 2020 – September 2023 TAS5441-Q1
PRODUCTION DATA
The following tables list operating modes and faults.
| STATE NAME | OUTPUT | OSCILLATOR | I2C (1) |
|---|---|---|---|
| STANDBY | Hi-Z, floating | Stopped | Inactive, Registers Reset, Non-blocking |
| Load diagnostic | DC biased | Active | Active |
| Mute (Hi-Z) / Fault | Hi-Z, floating | Active | Active |
| Play | Switching with audio | Active | Active |
| FAULT
EVENT |
FAULT
EVENT CATEGORY |
MONITORING MODES |
REPORTING METHOD |
ACTION
TYPE |
ACTION RESULT |
CLEARING | STANDBY |
|---|---|---|---|---|---|---|---|
| POR | Voltage fault | Mute (Hi-Z), Play | Not applicable | Hard mute (no ramp) | Standby | Self-clearing | Disabled |
| UV | I2C + FAULT pin | Hi-Z | |||||
| OV and Load dump(1) | Protected, No Reporting | ||||||
| OTSD | Thermal fault | Mute (Hi-Z), Play | I2C + FAULT pin | Disabled | |||
| OC fault | Output channel fault | Play | |||||
| DC detect | |||||||
| Load diagnostic - short | Diagnostic | Hi-Z | None | Hi-Z, re-run diagnostics | |||
| Load diagnostic - open | I2C | None | Clears on next diagnostic cycle |