ZHCSQD2I February   1994  – October 2022 SN55LBC180 , SN65LBC180 , SN75LBC180

PRODUCTION DATA  

  1. 特性
  2. 说明
  3. 说明(续)
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Dissipation Rating Table
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information Table
    5. 6.5 Driver Section
      1. 6.5.1 Electrical Characteristics
      2. 6.5.2 Switching Characteristics
      3. 6.5.3 Switching Characteristics: SN55LBC180
    6. 6.6 Receiver Section
      1. 6.6.1 Electrical Characteristics
      2. 6.6.2 Switching Characteristics
      3. 6.6.3 Switching Characteristics: SN55LBC180
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Function Tables
    2. 8.2 Schematics of Inputs and Outputs
  9. Application and Implementation
    1. 9.1 Application Information
  10. 10Device and Documentation Support
    1. 10.1 接收文档更新通知
    2. 10.2 支持资源
    3. 10.3 商标
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • D|14
  • RSA|16
  • N|14
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

See note (1)
UNIT
VCCSupply voltage range (2)–0.3 to 7V
VBUSBus voltage range (A, B, Y, Z)(2)–10 to 15V
Voltage range at D, R, DE, RE(2)–0.3 to VCC + 0.5V
Continuous total power dissipation(3)Internally limited
Total power dissipationSee Dissipation Rating Table
TstgStorage temperature range–65 to 150°C
IOReceiver output current range–50 to 50mA
ESDElectrostatic dischargeHBM (Human Body Model) EIA/JESD22-A114±4kV
MM (Machine Model) EIA/JESD22-A115400V
CDM (Charge Device Model) EIA/JESD22-C1011.5kV
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to GND.
The maximum operating junction temperature is internally limited. Use the dissipation rating table to operate below this temperature.