TRF1218EVM
TRF1218 Evaluierungsmodul
TRF1218EVM
Überblick
The TRF1218 evaluation module (EVM) is used to evaluate the TRF1218 device.
Merkmale
- Operates on a single 5V supply
- Designed for single-ended, 50Ω input matching
- TRF1218 50Ω differential output is matched to 100Ω differential via a Pi resistor network on board.
- Simple interface to the input and outputs through onboard 2.92mm RF connectors
- Power-down option available onboard using a jumper
HF-Volldifferenzverstärker (FDAs)
Bestellen Sie und beginnen Sie mit der Entwicklung
TRF1218EVM — TRF1218 – Evaluierungsmodul
TRF1218EVM — TRF1218 – Evaluierungsmodul
RF-CASCADE-CALC-TOOL — HF-Kaskadenrechner von TI
Unterstützte Produkte und Hardware
Produkte
Abwärtswandlungsmischer
HF-Blockverstärker
HF-Frontend-Module
HF-PLLs und Synthesizer
HF-Verstärker mit variabler Verstärkung (VGAs)
HF-Volldifferenzverstärker (FDAs)
IQ-Demodulatoren
IQ-Modulatoren
Produkte für die drahtlose Verbindung in der Automobilindustrie
Rauscharme HF-Verstärker (Low Noise Amplifiers, LNAs)
Weitere Drahtlosprodukte
Hardware-Entwicklung
Entwicklungskit
Evaluierungsplatine
RF-CASCADE-CALC-TOOL — HF-Kaskadenrechner von TI
TI RF cascade calculator
Produkte
Abwärtswandlungsmischer
HF-Blockverstärker
HF-Frontend-Module
HF-PLLs und Synthesizer
HF-Verstärker mit variabler Verstärkung (VGAs)
HF-Volldifferenzverstärker (FDAs)
IQ-Demodulatoren
IQ-Modulatoren
Produkte für die drahtlose Verbindung in der Automobilindustrie
Rauscharme HF-Verstärker (Low Noise Amplifiers, LNAs)
Weitere Drahtlosprodukte
Hardware-Entwicklung
Entwicklungskit
Evaluierungsplatine
Versionsinformationen
Overview
The RF Cascade Calculator is a web-based tool for performing RF signal chain (lineup) cascade analysis. It computes cascaded performance parameters across a multi-stage RF signal chain using standard cascade equations (Friis formula for noise figure, reciprocal power sums for IP3/IP2/P1dB, etc.).
The tool is hosted on the TI Developer Gallery and runs entirely in the user's browser — no software download or installation is required.
Features (v1.0.0)
RF Cascade Analysis
- Support for up to 10 cascaded stages
- Per-stage input parameters: Name, Gain, OIP3, OIP2, NF, OP1dB
- Configurable source power, source frequency, and analysis bandwidth
- Dynamic stage count (add/remove stages on the fly)
Cascade Calculations (Friis and Standard Cascade Equations)
- Cascade Gain (cumulative sum)
- Cascade Noise Figure
- Cascade OIP3
- Cascade OIP2
- Cascade OP1dB
- Output Power (Pout) per stage
Derived System-Level Results
- Total Cascade Gain (dB)
- Output Power / Pout (dBm)
- Cascade OIP3 / IIP3 (dBm)
- Cascade OIP2 / IIP2 (dBm)
- Cascade NF (dB)
- Cascade OP1dB / IP1dB (dBm)
- Output Noise Spectral Density / NSD (dBm/Hz)
- Output Noise Floor (dBm)
- Signal-to-Noise Ratio / SNR (dB)
- IMD3 (dBc)
- IMD2 (dBc)
- P1dB Saturation Detection with stage identification
Interactive Plot
- Dual-axis Plotly.js chart showing cascade parameters per stage
- Selectable left Y-axis parameter (Gain, OIP3, OIP2, NF, OP1dB)
- Selectable right Y-axis parameter (independent selection)
- Data-point annotations and hover tooltips
- Responsive layout
Input Validation
- Per-field validation with visual feedback (red = error, amber = warning)
- Range checking for all RF parameters
- Cross-field validation (e.g., OIP3 vs OP1dB consistency, passive NF check)
- Non-numeric and out-of-range detection
Tooltip Equations
- Hovering over any result field shows the formula and calculation breakdown
Export
- One-click CSV export of all inputs, cascade results, and derived results
- Organized into sections: Source Config, Per-Stage Inputs, Per-Stage Cascade Results, Overall Results, Derived Results, Saturation Status
Neuheiten
- v1.0.0
Technische Dokumentation
| Top-Dokumentation | Typ | Titel | Format-Optionen | Neueste englische Version herunterladen | Datum |
|---|---|---|---|---|---|
| * | EVM User's guide | TRF1218EVM Evaluation Module User's Guide: | PDF | HTML | 01.06.2026 |
Support und Schulungen
TI E2E™-Foren mit technischem Support von TI-Ingenieuren
Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.
Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support.