產品詳細資料

Device type Current sensing Output type Differential Peak-to-peak input voltage range (V) 0.05 Isolation rating Basic Withstand isolation voltage (VISO) (Vrms) 3000 Working isolation voltage (VIOWM) (Vrms) 1000 Transient isolation voltage (VIOTM) (VPK) 4250 CMTI (min) (kV/µs) 100 Creepage (min) (mm) 8.5 Clearance (min) (mm) 8.5 Input offset (±) (max) (V) 0.00005 Input offset drift (±) (typ) (µV/°C) 0.15 Rating Catalog Operating temperature range (°C) -40 to 125
Device type Current sensing Output type Differential Peak-to-peak input voltage range (V) 0.05 Isolation rating Basic Withstand isolation voltage (VISO) (Vrms) 3000 Working isolation voltage (VIOWM) (Vrms) 1000 Transient isolation voltage (VIOTM) (VPK) 4250 CMTI (min) (kV/µs) 100 Creepage (min) (mm) 8.5 Clearance (min) (mm) 8.5 Input offset (±) (max) (V) 0.00005 Input offset drift (±) (typ) (µV/°C) 0.15 Rating Catalog Operating temperature range (°C) -40 to 125
SOIC (DWV) 8 67.275 mm² (5.85 mm × 11.5 mm)
  • ±50-mV input voltage range optimized for current measurements using shunt resistors
  • Fixed gain: 41
  • Low DC errors:
    • Offset error: ±50 µV (max)
    • Offset drift: ±0.8 µV/°C (max)
    • Gain error: ±0.2% (max)
    • Gain drift: ±35 ppm/°C (max)
    • Nonlinearity: 0.03% (max)
  • 3.3-V or 5-V operation on high-side and low-side
  • Fail-safe output
  • High CMTI : 100 kV/µs (min)
  • Low EMI, meets CISPR-11 and CISPR-25 standards
  • Safety-related certifications:
    • 4250-VPK basic isolation per DIN VDE V 0884-11: 2017-01
    • 3000-VRMS isolation for 1 minute per UL1577
  • ±50-mV input voltage range optimized for current measurements using shunt resistors
  • Fixed gain: 41
  • Low DC errors:
    • Offset error: ±50 µV (max)
    • Offset drift: ±0.8 µV/°C (max)
    • Gain error: ±0.2% (max)
    • Gain drift: ±35 ppm/°C (max)
    • Nonlinearity: 0.03% (max)
  • 3.3-V or 5-V operation on high-side and low-side
  • Fail-safe output
  • High CMTI : 100 kV/µs (min)
  • Low EMI, meets CISPR-11 and CISPR-25 standards
  • Safety-related certifications:
    • 4250-VPK basic isolation per DIN VDE V 0884-11: 2017-01
    • 3000-VRMS isolation for 1 minute per UL1577

The AMC1202 is a precision, isolated amplifier with an output separated from the input circuitry by an isolation barrier that is highly resistant to magnetic interference. This barrier is certified to provide basic galvanic isolation of up to 3 kVRMS according to VDE V 0884-11 and UL1577, and supports a working voltage of up to 1 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC1202 is optimized for direct connection to a low-impedance shunt resistor or other low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current control in PFC stages, DC/DC converters, traction inverters, and OBCs over the full automotive temperature range from –40°C to +125°C.

The integrated missing shunt and missing high-side supply detection features simplify system-level design and diagnostics.

The AMC1202 is a precision, isolated amplifier with an output separated from the input circuitry by an isolation barrier that is highly resistant to magnetic interference. This barrier is certified to provide basic galvanic isolation of up to 3 kVRMS according to VDE V 0884-11 and UL1577, and supports a working voltage of up to 1 kVRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from hazardous voltages and damage.

The input of the AMC1202 is optimized for direct connection to a low-impedance shunt resistor or other low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current control in PFC stages, DC/DC converters, traction inverters, and OBCs over the full automotive temperature range from –40°C to +125°C.

The integrated missing shunt and missing high-side supply detection features simplify system-level design and diagnostics.

下載 觀看有字幕稿的影片 影片

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

AMC-AMP-50A-EVM — 適用於 ±50A AMCxx 放大器的評估模組

AMC-AMP-50A-EVM 是一款隔離式電流感測評估模組 (EVM),專為 ±50A 分流架構電流感測設計。此 EVM 可讓使用者透過外部分流電阻器感測高達 ±50A 峰值電流,同時透過 AMC3302 的隔離層測量隔離輸出。AMC3302 是一款針對分流架構電流量測最佳化的精密隔離式放大器,並與 Isabellenhütte BVN-BVN- M R001 分流電阻器配對。此 EVM 透過拼接提供在大電流下促進散熱,並可在 ±1% (典型) 準確度內運作。
使用指南: PDF | HTML
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
開發板

AMC1302EVM — 適用於 ±50-mV 輸入、高精密、強化型隔離放大器的 AMC1302 評估模組

AMC1302 評估模組 ( EVM) 是適用於評估 AMC1302 的平台,該元件是一款 7-kV 增強型隔離放大器,專為電流分流測量應用而設計。AMC1302EVM 允許使用者探索 AMC1302 裝置的所有功能。

使用指南: PDF
支援產品和硬體
有庫存
限制:
??asset.out-of-stock-ti_zh_TW??
無法提供
計算工具

SBAR013 — Isolated Amplifier Voltage Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a voltage sensing configuration.
支援產品和硬體
計算工具

SBAR020 — Isolated Amplifier Current Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a current sensing configuration.
支援產品和硬體
封裝 針腳 CAD 符號、佔位空間與 3D 模型
SOIC (DWV) 8 Ultra Librarian

訂購與品質

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片