产品详情

Technology family ACT Bits (#) 1 Rating Catalog Operating temperature range (°C) -55 to 125
Technology family ACT Bits (#) 1 Rating Catalog Operating temperature range (°C) -55 to 125
SOIC (D) 16 59.4 mm² (9.9 mm × 6 mm)
  • Speed of Bipolar FCT, AS, and S, With Significantly Reduced Power Consumption
  • Digital Design Avoids Analog Compensation Errors
  • Easily Cascadable for Higher-Order Loops
  • Useful Frequency Range
    • DC to 110 MHz Typical (K CLK)
    • DC to 70 MHz Typical (I/D CLK)
  • Dynamically Variable Bandwidth
  • Very Narrow Bandwidth Attainable
  • Power-On Reset
  • Output Capability
    • Standard: XORPD OUT, ECPD OUT
    • Bus Driver: I/D OUT
  • SCR Latch-Up-Resistant CMOS Process and Circuit Design
  • Balanced Propagation Delays
  • ESD Protection Exceeds 2000 V Per MIL-STD-883, Method 3015

  • Speed of Bipolar FCT, AS, and S, With Significantly Reduced Power Consumption
  • Digital Design Avoids Analog Compensation Errors
  • Easily Cascadable for Higher-Order Loops
  • Useful Frequency Range
    • DC to 110 MHz Typical (K CLK)
    • DC to 70 MHz Typical (I/D CLK)
  • Dynamically Variable Bandwidth
  • Very Narrow Bandwidth Attainable
  • Power-On Reset
  • Output Capability
    • Standard: XORPD OUT, ECPD OUT
    • Bus Driver: I/D OUT
  • SCR Latch-Up-Resistant CMOS Process and Circuit Design
  • Balanced Propagation Delays
  • ESD Protection Exceeds 2000 V Per MIL-STD-883, Method 3015

The CD74ACT297 provides a simple, cost-effective solution to high-accuracy, digital, phase-locked-loop applications. This device contains all the necessary circuits, with the exception of the divide-by-N counter, to build first-order phase-locked loops as shown in Figure 1.

Both exclusive-OR phase detectors (XORPDs) and edge-controlled (ECPD) phase detectors are provided for maximum flexibility.

Proper partitioning of the loop function, with many of the building blocks external to the package, makes it easy for the designer to incorporate ripple cancellation or to cascade to higher-order phase-locked loops.

The length of the up/down K counter is digitally programmable according to the K-counter function table. With A, B, C, and D all low, the K counter is disabled. With A high and B, C, and D low, the K counter is only three stages long, which widens the bandwidth, or capture range, and shortens the lock time of the loop. When A, B, C, and D are programmed high, the K counter becomes 17 stages long, which narrows the bandwidth, or capture range, and lengthens the lock time. Real-time control of loop bandwidth by manipulating the A-through-D inputs can maximize the overall performance of the digital phase-locked loop.

This device performs the classic first-order phase-locked-loop function without using analog components. The accuracy of the digital phase-locked loop (DPLL) is not affected by VCC and temperature variations, but depends solely on accuracies of the K clock (K CLK), increment/decrement clock (I/D CLK), and loop propagation delays. The I/D clock frequency and the divide-by-N modulos determine the center frequency of the DPLL. The center frequency is defined by the relationship fc = I/D clock/2N (Hz).

The CD74ACT297 provides a simple, cost-effective solution to high-accuracy, digital, phase-locked-loop applications. This device contains all the necessary circuits, with the exception of the divide-by-N counter, to build first-order phase-locked loops as shown in Figure 1.

Both exclusive-OR phase detectors (XORPDs) and edge-controlled (ECPD) phase detectors are provided for maximum flexibility.

Proper partitioning of the loop function, with many of the building blocks external to the package, makes it easy for the designer to incorporate ripple cancellation or to cascade to higher-order phase-locked loops.

The length of the up/down K counter is digitally programmable according to the K-counter function table. With A, B, C, and D all low, the K counter is disabled. With A high and B, C, and D low, the K counter is only three stages long, which widens the bandwidth, or capture range, and shortens the lock time of the loop. When A, B, C, and D are programmed high, the K counter becomes 17 stages long, which narrows the bandwidth, or capture range, and lengthens the lock time. Real-time control of loop bandwidth by manipulating the A-through-D inputs can maximize the overall performance of the digital phase-locked loop.

This device performs the classic first-order phase-locked-loop function without using analog components. The accuracy of the digital phase-locked loop (DPLL) is not affected by VCC and temperature variations, but depends solely on accuracies of the K clock (K CLK), increment/decrement clock (I/D CLK), and loop propagation delays. The I/D clock frequency and the divide-by-N modulos determine the center frequency of the DPLL. The center frequency is defined by the relationship fc = I/D clock/2N (Hz).

下载

您可能感兴趣的相似产品

open-in-new 比较替代产品
功能与比较器件相似。
LMK5B12204 正在供货 采用网络同步和 BAW 技术的超低抖动时钟发生器 Four output, low jitter, single BAW-based DPLL clock generator with network synchronization

技术文档

未找到结果。请清除搜索并重试。
查看全部 1
顶层文档 类型 标题 格式选项 下载最新的英语版本 日期
* 数据表 Digital Phase-Locked Loop 数据表 (Rev. D) 2002-6-27

订购和质量

支持和培训

可获得 TI 工程师技术支持的 TI E2E™ 论坛

所有内容均由 TI 和社区贡献者按“原样”提供,并不构成 TI 规范。请参阅使用条款

如果您对质量、包装或订购 TI 产品有疑问,请参阅 TI 支持。​​​​​​​​​​​​​​