AFE159RP4
- Integrated Signal Chain for ECG, Pace Detection, and Respiration Measurement
- ECG Receiver
- Four high resolution channels at low power of 0.42mW/channel
- Flexible four leads selectable from six electrodes
- Programmable gain: 1.25 to 9
- Input-referred noise: 4µVPP in 150Hz BW
- Differential input range: ±1V with Gain = 4
- CMRR: -140dB
- Data rate: 125SPS to 128kSPS
- Pace Detection
- On-chip digital pace detection algorithm on programmable two leads
- High-speed 128kSPS pace output on two channels for software pace detection
- Respiration
- Low-noise of 24mΩPP with 2kΩ body impedance and 1kΩ defibrillator protection resistor on each electrode
- Supports Sine and Square wave excitation
- Other Features
- Built-in right leg drive amplifier steerable to any electrode
- DC lead-off detection, AC lead impedance detection, Wilson Center Terminal (WCT), Goldberger Central Terminals (GCT), test signals
- Battery voltage monitoring
- Flexible power-down and standby modes
- Built-in oscillator, PLL, and reference
- 1k sample main FIFO and 2k sample pace FIFO
- SPI-compatible serial interface
- Analog supply voltage 1: 3.15V to 5.25V
- Analog supply voltage 2: 1.7V to 1.9V
- I/O supply voltage: 1.65V to 3.6V
- Supports systems meeting AAMI EC11, AMI EC13, AMI EC38, IEC60601-1, IEC60601-2-25, IEC60601-2-27, and IEC60601-2-51 standards
The AFE1594 is a family of multichannel, simultaneous sampling, 24-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with built-in programmable gain Instrumentation Amplifiers (INAs), internal reference, and an on-chip PLL. The AFE supports digital pace pulse detection, thoracic impedance measurement and incorporates all of the features that are commonly required in medical electrocardiogram (ECG) and electroencephalogram (EEG) applications. Multiple AFE159x devices can be cascaded in high channel count systems. With high levels of integration and exceptional performance, the AFE159x enables the development of scalable medical instrumentation systems at significantly reduced size, power, and overall cost.
申请了解更多信息
可提供完整的数据表。立即申请
技术文档
| 顶层文档 | 类型 | 标题 | 格式选项 | 下载最新的英语版本 | 日期 | |
|---|---|---|---|---|---|---|
| * | 数据表 | AFE159x Low-Power, 4-Channel, 24-Bit Analog Front-Ends for Bio-Potential Measurements 数据表 (Rev. A) | PDF | HTML | 2024-11-12 |
设计与开发
如需其他信息或资源,请点击以下任一标题进入详情页面查看(如有)。
AFE1594EVM — AFE1594 评估模块
AFE159RP4-DESIGN — AFE159RP4 design resources
TIDA-010280-DESIGN — TIDA-010280 user guide, design files, and firmware
TIDA-010288-DESIGN — TIDA-010288 user guide, design files, and firmware
TIDA-010280 — 具有呼吸、起搏和体温检测功能的小型无线 6 导联 ECG 动态心电图监测仪参考设计
该可穿戴生物传感动态心电图监测仪参考设计提供了一个评估平台,用于评估 TI 持续监测心电图 (ECG)、心率、呼吸、起搏脉冲、体温和运动等生命体征的最新产品。该设计利用 AFE159RP4 通过最多 6 个导联(4 个通道)进行低功耗、高分辨率和高度集成的 ECG 信号采集,并利用 TMP119 进行体温监测。测量数据由 CC2674R10(支持低功耗 Bluetooth® 5.3)传输至智能手机或医疗监测系统等远程终端,以实现实时显示。板载发光二极管 (LED) 可指示系统状态,例如导联脱落、电量低以及低功耗 Bluetooth® 连接。整个系统可以由 2 颗 CR2032 电池(3V (...)
TIDA-010288 — 支持边缘 AI 的无线 ECG 动态心电图监护仪参考设计,适用于实时心律失常分类
| 封装 | 引脚 | CAD 符号、封装和 3D 模型 |
|---|---|---|
| VQFN (RGZ) | 48 | Ultra Librarian |
| DSBGA (YAF) | 49 | Ultra Librarian |
订购和质量
推荐产品可能包含与 TI 此产品相关的参数、评估模块或参考设计。