SNAK010 April 2022 ADC128S102-SEP
Table 1-1 lists the device information used for TID HDR characterization and qualification.
TID HDR Details: up to 30 krad(Si) | |
---|---|
TI device number | ADC128S102PWTSEP |
Package | 16-pin TSSOP (PW) |
Technology | CMOS7 |
Die lot number | 1012690CUA |
Die name | GHX3UADC128SA0 |
Device / package lot number | 1362809EM1 |
Lot trace code (LTC) | 1BCGDCK |
Quantity tested | 22 |
Lot accept/reject | All 22 devices passed 30 krad (Si) |
HDR radiation facility | Texas Instruments SVC Group, Santa Clara, CA |
HDR dose level | 30krad (Si) |
HDR dose rate | 51.61 rads (Si) / sec |
HDR irradiation temperature | Ambient, room temperature |
Radiation test date | 24-Feb-2022 |
TI may provide technical, applications or design advice, quality characterization, and reliability data or service providing these items shall not expand or otherwise affect TI's warranties as set forth in the Texas Instruments Incorporated Standard Terms and Conditions of Sale for Semiconductor Products and no obligation or liability shall arise from TI's provision of such items. Semiconductor Products and no obligation or liability shall arise from TI's provision of such items.