SLVK033A February   2019  – August 2021 INA240-SEP

 

  1.   Trademarks
  2. 1Device Information
    1. 1.1 Device Details
  3. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Biased
    4. 2.4 Test Configuration and Condition
  4. 3Tested Parameters
  5. 4Total Ionizing Dose (RHA) Characterization Test Results
    1. 4.1 Offset Voltage
    2. 4.2 Gain Error
  6.   A Total Ionizing Dose HDR Report
  7.   B Revision History

Device Details

Table 1-1 lists the device information used for TID HDR characterization and qualification.

Table 1-1 Device and Exposure Details
TID HDR Details: up to 30 krad(Si)
TI Device NumberINA240-SEP
Package8-pin PW (TSSOP)
TechnologyABCD6
Die Lot Number7004590
A/T Lot Number / Date Code1084349/8AD3PDK
Quantity Tested37 irradiated devices + 3 control
Lot Accept/RejectDevices passed 3 krad(Si), 10 krad(Si), 20 krad(Si), 30 krad(Si)
HDR Radiation FacilityTexas Instruments SVA Group, Santa Clara, CA
HDR Dose Level3 krad(Si), 10 krad(Si), 20 krad(Si), 30 krad(Si)
HDR Dose Rate78 rad(Si)/s
HDR Radiation SourceGammacell 220 Excel (GC-220E) Co-60
Irradiation TemperatureAmbient, room temperature