over operating free-air temperature range (unless otherwise noted)(1) | | | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage
range | –0.5 | 6.5 | V |
| VI | Input voltage
range(2) | –0.5 | 6.5 | V |
| VO | Voltage range applied to Y output in the high-impedance or power-off state(2) | –0.5 | 6.5 | V |
| VO | Voltage range applied to any output in the high or low state(2)(3) | –0.5 | VCC + 0.5 | V |
| IIK | Input clamp current | VI < 0 | | –50 | mA |
| IOK | Output clamp current | VO < 0 | | –50 | mA |
| IO | Continuous output
current | | ±50 | mA |
| Continuous current
through VCC or GND | | ±100 | mA |
| Tstg |
Storage
temperature range |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage.
Absolute Maximum Ratings do not imply functional operation of the device at these or any
other conditions beyond those listed under Recommended Operating Conditions. If used
outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability, functionality,
performance, and shorten the device lifetime.
(2) The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The value of VCC is provided in the Recommended Operating Conditions table.