over operating free-air temperature range (unless otherwise noted) (1)
|
MIN |
TYP |
MAX |
UNIT |
| VCC |
Supply
voltage range(2) |
–0.5 |
|
4 |
V |
|
Input voltage range |
RE, FSEN |
–0.5 |
|
4 |
V |
| A or B |
–1.8 |
|
4 |
V |
|
Output
voltage range |
R |
–0.3 |
|
4 |
V |
| PD |
RE at 0V, CL = 15pF,
VID = 400mV, 125MHz |
|
|
339 |
mW |
| Tstg |
Storage
Temperature |
–65 |
|
150 |
°C |
(1) Stresses beyond those listed under absolute maximum
ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other
conditions beyond those indicated under recommended operating conditions
is not implied. Exposure to absolute-maximum-rated conditions for extended
periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are
with respect to network ground terminal.