| 参数 | 测试条件 | 最小值 | 典型值 | 最大值 | 单位 | |
|---|---|---|---|---|---|---|
| 输入 | ||||||
| VCM | 共模输入范围 | TA = -40°C 至 +125°C | -0.3 | 85 | V | |
| VVBUS | 总线电压输入范围 | 0 | 85 | V | ||
| CMRR | 共模抑制 | –0.3V < VCM < 85V,TA = –40°C 至 +125°C | 120 | 140 | dB | |
| VDIFF | 分流电压输入范围 | TA = –40°C 至 +125°C,ADCRANGE = 0 | -163.84 | 163.84 | mV | |
| TA = –40°C 至 +125°C,ADCRANGE = 1 | -40.96 | 40.96 | mV | |||
| Vos | 分流失调电压 | VCM = 0V | ±15 | ±50 | µV | |
| dVos/dT | 分流失调电压漂移 | TA = -40°C 至 +125°C | ±2 | ±20 | nV/°C | |
| PSRR | 分流失调电压与电源间的关系 | VS = 2.7 V 至 5.5V,TA = -40°C 至 +125°C | ±0.1 | ±1 | µV/V | |
| Vos_bus | VBUS 失调电压 | VBUS = 20mV | ±1 | ±5 | mV | |
| dVos/dT | VBUS 失调电压偏移 | TA = -40°C 至 +125°C | ±20 | ±100 | µV/°C | |
| PSRR | VBUS 失调电压与电源间的关系 | VS = 2.7V 至 5.5V | ±1.1 | mV/V | ||
| IB | 输入偏置电流 | 任一输入 IN+ 或 IN–,VCM = 85V | 0.1 | 2.5 | nA | |
| ZVBUS | VBUS 引脚输入阻抗 | 工作模式 | 0.8 | 1 | 1.2 | MΩ |
| IVBUS | VBUS 引脚漏电流 | 关断模式,VBUS = 85V | 10 | nA | ||
| RDIFF | 输入差分阻抗 | 活动模式,VIN+ – VIN– < 164mV | 92 | kΩ | ||
| 直流精度 | ||||||
| GSERR | 分流电压增益误差 | ±0.1 | ±0.3 | % | ||
| GS_DRFT | 分流电压增益误差漂移 | ±50 | ppm/°C | |||
| GBERR | VBUS 电压增益误差 | ±0.1 | ±0.3 | % | ||
| GB_DRFT | VBUS 电压增益误差偏移 | ±50 | ppm/°C | |||
| PTME | 功率总测量误差 (TME) | TA = –40°C 至 +125°C,处于满量程 | ±1.6 | % | ||
| ADC 分辨率 | 16 | 位 | ||||
| 1 个最低有效位 (LSB) 阶跃幅度 | 分流电压,ADCRANGE = 0 | 5 | µV | |||
| 分流电压,ADCRANGE = 1 | 1.25 | µV | ||||
| 总线电压 | 3.125 | mV | ||||
| 温度 | 125 | m°C | ||||
| TCT | ADC 转换时间(1) | 转换时间字段 = 0h | 50 | µs | ||
| 转换时间字段 = 1h | 84 | |||||
| 转换时间字段 = 2h | 150 | |||||
| 转换时间字段 = 3h | 280 | |||||
| 转换时间字段 = 4h | 540 | |||||
| 转换时间字段 = 5h | 1052 | |||||
| 转换时间字段 = 6h | 2074 | |||||
| 转换时间字段 = 7h | 4120 | |||||
| INL | 积分非线性 | ±2 | m% | |||
| DNL | 微分非线性 | 0.2 | LSB | |||
| 时钟源 | ||||||
| FOSC | 内部振荡器频率 | 1 | MHz | |||
| FOSC_TOL | 内部振荡器频率容限 | TA = 25°C | ±0.5 | % | ||
| TA = -40°C 至 +125°C | ±1 | % | ||||
| 温度传感器 | ||||||
| 测量范围 | -40 | +125 | °C | |||
| 温度精度 | TA = 25°C | ±0.15 | ±1 | °C | ||
| TA = -40°C 至 +125°C | ±0.2 | ±2 | °C | |||
| 电源 | ||||||
| VS | 电源电压 | 2.7 | 5.5 | V | ||
| IQ | 静态电流 | VSENSE = 0V | 640 | 750 | µA | |
| VSENSE = 0V,TA = –40°C 至 +125°C | 1.1 | mA | ||||
| IQSD | 静态电流,关断 | 关断模式 | 2.8 | 5 | µA | |
| TPOR | 器件启动时间 | 加电 (NPOR) | 300 | µs | ||
| 从关断模式 | 60 | |||||
| 数字输入/输出 | ||||||
| VIH | 逻辑输入电平,高 | SDA、SCL | 1.2 | 5.5 | V | |
| VIL | 逻辑输入电平,低 | GND | 0.4 | V | ||
| VOL | 逻辑输出电平,低 | IOL = 3mA | GND | 0.4 | V | |
| IIO_LEAK | 数字泄漏输入电流 | 0 ≤ VIN ≤ VS | -1 | 1 | µA | |