TI recommends the board have matched impedance of 50 Ω ±10% for all signals. The following table lists the exceptions.
| SIGNAL TYPE | SIGNAL NAME | IMPEDANCE (Ω) |
|---|---|---|
|
A channel LVDS differential pairs |
D_AP(0:15), D_AN(0:15) | 100 ±10% differential across each pair |
| DCLK_AP, DCLK_AN | ||
| SCTRL_AP, SCTRL_AN | ||
| B channel LVDS differential pairs | D_BP(0:15), D_BN(0:15) | 100 ±10% differential across each pair |
| DCLK_BP, DCLK_BN | ||
| SCTRL_BP, SCTRL_BN |