ZHCSTD7A December   2021  – November 2023 BQ79631-Q1

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Revision History
  6. 说明(续)
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements
    7. 7.7 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Measurement System
        1. 8.3.1.1 Voltage Measurement System
          1. 8.3.1.1.1 Main ADC
            1. 8.3.1.1.1.1 VS Voltage Measurements
              1. 8.3.1.1.1.1.1 Analog Front End
              2. 8.3.1.1.1.1.2 VS Channel Measurements
              3. 8.3.1.1.1.1.3 Post-ADC Digital LPF
              4. 8.3.1.1.1.1.4 SRP and SRN Measurements
            2. 8.3.1.1.1.2 Temperature Measurements
              1. 8.3.1.1.1.2.1 DieTemp1 Measurement
              2. 8.3.1.1.1.2.2 GPIOs and TSREF Measurements
            3. 8.3.1.1.1.3 Main ADC Operation Control
              1. 8.3.1.1.1.3.1 Operation Modes and Status
          2. 8.3.1.1.2 AUX ADC
            1. 8.3.1.1.2.1 AUX Voltage Measurements
              1. 8.3.1.1.2.1.1 AUX Analog Front End
              2. 8.3.1.1.2.1.2 AUX Channel Measurements
            2. 8.3.1.1.2.2 AUX Temperature Measurements
              1. 8.3.1.1.2.2.1 DieTemp2 Measurement
              2. 8.3.1.1.2.2.2 AUX GPIO Measurements
            3. 8.3.1.1.2.3 MISC Measurements
            4. 8.3.1.1.2.4 AUX ADC Operation Control
          3. 8.3.1.1.3 Synchronization Between MAIN and AUX ADC Measurements
        2. 8.3.1.2 Current Sense ADC
      2. 8.3.2 OVUV Detection
        1. 8.3.2.1 OVUV Operation Modes
        2. 8.3.2.2 OVUV Control and Status
          1. 8.3.2.2.1 OVUV Control
          2. 8.3.2.2.2 OVUV Status
      3. 8.3.3 Power Supplies
        1. 8.3.3.1 AVAO_REF and AVDD_REF
        2. 8.3.3.2 LDOIN
        3. 8.3.3.3 AVDD
        4. 8.3.3.4 DVDD
        5. 8.3.3.5 CVDD and NEG5V
        6. 8.3.3.6 TSREF
      4. 8.3.4 GPIO Configuration
      5. 8.3.5 Communication, OTP, Diagnostic Control
        1. 8.3.5.1 Communication
          1. 8.3.5.1.1 Serial Interface
            1. 8.3.5.1.1.1 UART Physical Layer
              1. 8.3.5.1.1.1.1 UART Transmitter
              2. 8.3.5.1.1.1.2 UART Receiver
              3. 8.3.5.1.1.1.3 COMM CLEAR
            2. 8.3.5.1.1.2 Command and Response Protocol
              1. 8.3.5.1.1.2.1 Transaction Frame Structure
                1. 8.3.5.1.1.2.1.1 Frame Initialization Byte
                2. 8.3.5.1.1.2.1.2 Device Address Byte
                3. 8.3.5.1.1.2.1.3 Register Address Bytes
                4. 8.3.5.1.1.2.1.4 Data Bytes
                5. 8.3.5.1.1.2.1.5 CRC Bytes
                6. 8.3.5.1.1.2.1.6 Calculating Frame CRC Value
                7. 8.3.5.1.1.2.1.7 Verifying Frame CRC
              2. 8.3.5.1.1.2.2 Transaction Frame Examples
                1. 8.3.5.1.1.2.2.1 Single Device Read/Write
                2. 8.3.5.1.1.2.2.2 Stack Read/Write
                3. 8.3.5.1.1.2.2.3 Broadcast Read/Write
                4. 8.3.5.1.1.2.2.4 Broadcast Write Reverse Direction
          2. 8.3.5.1.2 Daisy-Chain Interface
            1. 8.3.5.1.2.1 Daisy-Chain Transmitter and Receiver Functionality
            2. 8.3.5.1.2.2 Daisy-Chain Protocol
          3. 8.3.5.1.3 Start Communication
            1. 8.3.5.1.3.1 Identify Base and Stack
            2. 8.3.5.1.3.2 Auto-Addressing
              1. 8.3.5.1.3.2.1 Setting Up the Device Addresses
              2. 8.3.5.1.3.2.2 Setting Up COMM_CTRL[STACK_DEV] and [TOP_STACK]
              3. 8.3.5.1.3.2.3 Storing Device Address to OTP
            3. 8.3.5.1.3.3 Synchronize Daisy-Chain DLL
            4. 8.3.5.1.3.4 Ring Communication
          4. 8.3.5.1.4 Communication Timeout
            1. 8.3.5.1.4.1 Short Communication Timeout
            2. 8.3.5.1.4.2 Long Communication Timeout
          5. 8.3.5.1.5 Communication Debug Mode
          6. 8.3.5.1.6 Multidrop Configuration
          7. 8.3.5.1.7 SPI Master
          8. 8.3.5.1.8 SPI Loopback
        2. 8.3.5.2 Fault Handling
          1. 8.3.5.2.1 Fault Status Hierarchy
            1. 8.3.5.2.1.1 Debug Registers
          2. 8.3.5.2.2 Fault Masking and Reset
            1. 8.3.5.2.2.1 Fault Masking
            2. 8.3.5.2.2.2 Fault Reset
          3. 8.3.5.2.3 Fault Signaling
            1. 8.3.5.2.3.1 Fault Status Transmitting in ACTIVE Mode
            2. 8.3.5.2.3.2 Fault Status Transmitting in SLEEP Mode
            3. 8.3.5.2.3.3 Heartbeat and Fault Tone
        3. 8.3.5.3 Nonvolatile Memory
          1. 8.3.5.3.1 OTP Page Status
          2. 8.3.5.3.2 OTP Programming
        4. 8.3.5.4 Diagnostic Control/Status
          1. 8.3.5.4.1 Power Supplies Check
            1. 8.3.5.4.1.1 Power Supply Diagnostic Check
            2. 8.3.5.4.1.2 Power Supply BIST
          2. 8.3.5.4.2 Thermal Shutdown and Warning Check
            1. 8.3.5.4.2.1 Thermal Shutdown
            2. 8.3.5.4.2.2 Thermal Warning
          3. 8.3.5.4.3 Oscillators Watchdog
          4. 8.3.5.4.4 OTP Error Check
            1. 8.3.5.4.4.1 OTP CRC Test and Faults
            2. 8.3.5.4.4.2 OTP Margin Read
            3. 8.3.5.4.4.3 Error Check and Correct (ECC) OTP
          5. 8.3.5.4.5 OVUV Detection Check
            1. 8.3.5.4.5.1 Parity Check
            2. 8.3.5.4.5.2 OVUV DAC Check
            3. 8.3.5.4.5.3 OVUV Protector BIST
          6. 8.3.5.4.6 Diagnostic Through ADC Comparison
            1. 8.3.5.4.6.1 VS Voltage Measurement Check
            2. 8.3.5.4.6.2 Temperature Measurement Check
            3. 8.3.5.4.6.3 VS and AUX Open Wire Check
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power Modes
        1. 8.4.1.1 SHUTDOWN Mode
          1. 8.4.1.1.1 Exit SHUTDOWN Mode
          2. 8.4.1.1.2 Enter SHUTDOWN Mode
        2. 8.4.1.2 SLEEP Mode
          1. 8.4.1.2.1 Exit SLEEP Mode
          2. 8.4.1.2.2 Enter SLEEP Mode
        3. 8.4.1.3 ACTIVE Mode
          1. 8.4.1.3.1 Exit ACTIVE Mode
          2. 8.4.1.3.2 Enter ACTIVE Mode From SHUTDOWN Mode
          3. 8.4.1.3.3 Enter ACTIVE Mode From SLEEP Mode
      2. 8.4.2 Device Reset
      3. 8.4.3 Ping and Tone
        1. 8.4.3.1 Ping
        2. 8.4.3.2 Tone
        3. 8.4.3.3 Ping and Tone Propagation
    5. 8.5 Register Maps
      1. 8.5.1 OTP Shadow Register Summary
      2. 8.5.2 Read/Write Register Summary
      3. 8.5.3 Read-Only Register Summary
      4. 8.5.4 Register Field Descriptions
        1. 8.5.4.1  Device Addressing Setup
          1. 8.5.4.1.1 DIR0_ADDR_OTP
          2. 8.5.4.1.2 DIR1_ADDR_OTP
          3. 8.5.4.1.3 CUST_MISC1 through CUST_MISC8
          4. 8.5.4.1.4 DIR0_ADDR
          5. 8.5.4.1.5 DIR1_ADDR
        2. 8.5.4.2  Device ID and Scratch Pad
          1. 8.5.4.2.1 PARTID
          2. 8.5.4.2.2 DEV_REVID
          3. 8.5.4.2.3 DIE_ID1 through DIE_ID9
        3. 8.5.4.3  General Configuration and Control
          1. 8.5.4.3.1  DEV_CONF
          2. 8.5.4.3.2  PWR_TRANSIT_CONF
          3. 8.5.4.3.3  COMM_TIMEOUT_CONF
          4. 8.5.4.3.4  TX_HOLD_OFF
          5. 8.5.4.3.5  STACK_RESPONSE
          6. 8.5.4.3.6  COMM_CTRL
          7. 8.5.4.3.7  CONTROL1
          8. 8.5.4.3.8  CONTROL2
          9. 8.5.4.3.9  CUST_CRC_HI
          10. 8.5.4.3.10 CUST_CRC_LO
          11. 8.5.4.3.11 CUST_CRC_RSLT_HI
          12. 8.5.4.3.12 CUST_CRC_RSLT_LO
        4. 8.5.4.4  Operation Status
          1. 8.5.4.4.1 DIAG_STAT
          2. 8.5.4.4.2 ADC_STAT1
          3. 8.5.4.4.3 ADC_STAT2
          4. 8.5.4.4.4 GPIO_STAT
          5. 8.5.4.4.5 DEV_STAT
        5. 8.5.4.5  ADC Configuration and Control
          1. 8.5.4.5.1  ADC_CONF1
          2. 8.5.4.5.2  ADC_CONF2
          3. 8.5.4.5.3  MAIN_ADC_CAL1
          4. 8.5.4.5.4  MAIN_ADC_CAL2
          5. 8.5.4.5.5  AUX_ADC_CAL1
          6. 8.5.4.5.6  AUX_ADC_CAL2
          7. 8.5.4.5.7  CS_ADC_CAL1
          8. 8.5.4.5.8  CS_ADC_CAL2
          9. 8.5.4.5.9  ADC_CTRL1
          10. 8.5.4.5.10 ADC_CTRL2
          11. 8.5.4.5.11 ADC_CTRL3
        6. 8.5.4.6  ADC Measurement Results
          1. 8.5.4.6.1  VS16_HI/LO
          2. 8.5.4.6.2  VS15_HI/LO
          3. 8.5.4.6.3  VS14_HI/LO
          4. 8.5.4.6.4  VS13_HI/LO
          5. 8.5.4.6.5  VS12_HI/LO
          6. 8.5.4.6.6  VS11_HI/LO
          7. 8.5.4.6.7  VS10_HI/LO
          8. 8.5.4.6.8  VS9_HI/LO
          9. 8.5.4.6.9  VS8_HI/LO
          10. 8.5.4.6.10 VS7_HI/LO
          11. 8.5.4.6.11 VS6_HI/LO
          12. 8.5.4.6.12 VS5_HI/LO
          13. 8.5.4.6.13 VS4_HI/LO
          14. 8.5.4.6.14 VS3_HI/LO
          15. 8.5.4.6.15 VS2_HI/LO
          16. 8.5.4.6.16 VS1_HI/LO
          17. 8.5.4.6.17 CSAUX_HI/LO
          18. 8.5.4.6.18 TSREF_HI/LO
          19. 8.5.4.6.19 GPIO1_HI/LO
          20. 8.5.4.6.20 GPIO2_HI/LO
          21. 8.5.4.6.21 GPIO3_HI/LO
          22. 8.5.4.6.22 GPIO4_HI/LO
          23. 8.5.4.6.23 GPIO5_HI/LO
          24. 8.5.4.6.24 GPIO6_HI/LO
          25. 8.5.4.6.25 GPIO7_HI/LO
          26. 8.5.4.6.26 GPIO8_HI/LO
          27. 8.5.4.6.27 DIETEMP1_HI/LO
          28. 8.5.4.6.28 DIETEMP2_HI/LO
          29. 8.5.4.6.29 AUX_IN_HI/LO
          30. 8.5.4.6.30 AUX_GPIO_HI/LO
          31. 8.5.4.6.31 AUX_PWR_HI/LO
          32. 8.5.4.6.32 AUX_REFL_HI/LO
          33. 8.5.4.6.33 AUX_VBG2_HI/LO
          34. 8.5.4.6.34 AUX_AVAO_REF_HI/LO
          35. 8.5.4.6.35 AUX_AVDD_REF_HI/LO
          36. 8.5.4.6.36 AUX_OV_DAC_HI/LO
          37. 8.5.4.6.37 AUX_UV_DAC_HI/LO
          38. 8.5.4.6.38 AUX_VCM1_HI/LO
          39. 8.5.4.6.39 REFH_HI/LO
          40. 8.5.4.6.40 DIAG_MAIN_HI/LO
          41. 8.5.4.6.41 DIAG_AUX_HI/LO
          42. 8.5.4.6.42 CURRENT_HI/MID/LO
        7. 8.5.4.7  Protector Configuration and Control
          1. 8.5.4.7.1 OV_THRESH
          2. 8.5.4.7.2 UV_THRESH
          3. 8.5.4.7.3 UV_DISABLE1
          4. 8.5.4.7.4 UV_DISABLE2
          5. 8.5.4.7.5 OVUV_CTRL
        8. 8.5.4.8  GPIO Configuration
          1. 8.5.4.8.1 GPIO_CONF1
          2. 8.5.4.8.2 GPIO_CONF2
          3. 8.5.4.8.3 GPIO_CONF3
          4. 8.5.4.8.4 GPIO_CONF4
        9. 8.5.4.9  SPI Master
          1. 8.5.4.9.1 SPI_CONF
          2. 8.5.4.9.2 SPI_EXE
          3. 8.5.4.9.3 SPI_TX3, SPI_TX2, and SPI_TX1
          4. 8.5.4.9.4 SPI_RX3, SPI_RX2, and SPI_RX1
        10. 8.5.4.10 Diagnostic Control
          1. 8.5.4.10.1 DIAG_OTP_CTRL
          2. 8.5.4.10.2 DIAG_COMM_CTRL
          3. 8.5.4.10.3 DIAG_PWR_CTRL
          4. 8.5.4.10.4 DIAG_COMP_CTRL1
          5. 8.5.4.10.5 DIAG_COMP_CTRL2
          6. 8.5.4.10.6 DIAG_COMP_CTRL3
          7. 8.5.4.10.7 DIAG_COMP_CTRL4
          8. 8.5.4.10.8 DIAG_PROT_CTRL
        11. 8.5.4.11 Fault Configuration and Reset
          1. 8.5.4.11.1 FAULT_MSK1
          2. 8.5.4.11.2 FAULT_MSK2
          3. 8.5.4.11.3 FAULT_RST1
          4. 8.5.4.11.4 FAULT_RST2
        12. 8.5.4.12 Fault Status
          1. 8.5.4.12.1  FAULT_SUMMARY
          2. 8.5.4.12.2  FAULT_COMM1
          3. 8.5.4.12.3  FAULT_COMM2
          4. 8.5.4.12.4  FAULT_COMM3
          5. 8.5.4.12.5  FAULT_OTP
          6. 8.5.4.12.6  FAULT_SYS
          7. 8.5.4.12.7  FAULT_PROT1
          8. 8.5.4.12.8  FAULT_PROT2
          9. 8.5.4.12.9  FAULT_OV1
          10. 8.5.4.12.10 FAULT_OV2
          11. 8.5.4.12.11 FAULT_UV1
          12. 8.5.4.12.12 FAULT_UV2
          13. 8.5.4.12.13 FAULT_COMP_GPIO
          14. 8.5.4.12.14 FAULT_COMP_VSAUX1
          15. 8.5.4.12.15 FAULT_COMP_VSAUX2
          16. 8.5.4.12.16 FAULT_COMP_VSOW1
          17. 8.5.4.12.17 FAULT_COMP_VSOW2
          18. 8.5.4.12.18 FAULT_COMP_AUXOW1
          19. 8.5.4.12.19 FAULT_COMP_AUXOW2
          20. 8.5.4.12.20 FAULT_COMP_MISC
          21. 8.5.4.12.21 FAULT_PWR1
          22. 8.5.4.12.22 FAULT_PWR2
          23. 8.5.4.12.23 FAULT_PWR3
        13. 8.5.4.13 Debug Control and Status
          1. 8.5.4.13.1  DEBUG_CTRL_UNLOCK
          2. 8.5.4.13.2  DEBUG_COMM_CTRL1
          3. 8.5.4.13.3  DEBUG_COMM_CTRL2
          4. 8.5.4.13.4  DEBUG_COMM_STAT
          5. 8.5.4.13.5  DEBUG_UART_RC
          6. 8.5.4.13.6  DEBUG_UART_RR_TR
          7. 8.5.4.13.7  DEBUG_COMH_BIT
          8. 8.5.4.13.8  DEBUG_COMH_RC
          9. 8.5.4.13.9  DEBUG_COMH_RR_TR
          10. 8.5.4.13.10 DEBUG_COML_BIT
          11. 8.5.4.13.11 DEBUG_COML_RC
          12. 8.5.4.13.12 DEBUG_COML_RR_TR
          13. 8.5.4.13.13 DEBUG_UART_DISCARD
          14. 8.5.4.13.14 DEBUG_COMH_DISCARD
          15. 8.5.4.13.15 DEBUG_COML_DISCARD
          16. 8.5.4.13.16 DEBUG_UART_VALID_HI/LO
          17. 8.5.4.13.17 DEBUG_COMH_VALID_HI/LO
          18. 8.5.4.13.18 DEBUG_COML_VALID_HI/LO
          19. 8.5.4.13.19 DEBUG_OTP_SEC_BLK
          20. 8.5.4.13.20 DEBUG_OTP_DED_BLK
        14. 8.5.4.14 OTP Programming Control and Status
          1. 8.5.4.14.1 OTP_PROG_UNLOCK1A through OTP_PROG_UNLOCK1D
          2. 8.5.4.14.2 OTP_PROG_UNLOCK2A through OTP_PROG_UNLOCK2D
          3. 8.5.4.14.3 OTP_PROG_CTRL
          4. 8.5.4.14.4 OTP_ECC_TEST
          5. 8.5.4.14.5 OTP_ECC_DATAIN1 through OTP_ECC_DATAIN9
          6. 8.5.4.14.6 OTP_ECC_DATAOUT1 through OTP_ECC_DATAOUT9
          7. 8.5.4.14.7 OTP_PROG_STAT
          8. 8.5.4.14.8 OTP_CUST1_STAT
          9. 8.5.4.14.9 OTP_CUST2_STAT
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Base Device Application Circuit
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1  PACK+ and FUSE Measurement
          2. 9.2.1.2.2  Insulation Measurement
          3. 9.2.1.2.3  LINK+/- Measurement
          4. 9.2.1.2.4  CHARGE+/– Measurement
          5. 9.2.1.2.5  Overcurrent Detection Scheme Using OVUV Comparators
          6. 9.2.1.2.6  Unused Pins
          7. 9.2.1.2.7  Current Sense Input
          8. 9.2.1.2.8  VPWR and External NPN
          9. 9.2.1.2.9  Power Supplies, Reference Input
          10. 9.2.1.2.10 GPIO For Thermistor Inputs
          11. 9.2.1.2.11 UART, NFAULT
          12. 9.2.1.2.12 Daisy-Chain Isolation
            1. 9.2.1.2.12.1 Devices Connected on the Same PCB
            2. 9.2.1.2.12.2 Devices Connected on Different PCBs
        3. 9.2.1.3 Application Curve
      2. 9.2.2 Daisy Device Application Circuit
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 Ground Planes
      2. 11.1.2 Bypass Capacitors for Power Supplies and Reference
      3. 11.1.3 Voltage Sensing
      4. 11.1.4 Daisy-Chain Communication
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 第三方产品免责声明
    2. 12.2 接收文档更新通知
    3. 12.3 支持资源
    4. 12.4 Trademarks
    5. 12.5 静电放电警告
    6. 12.6 术语表
  14. 13Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息
DEBUG_COMH_RC
Address0x0784
Read OnlyBit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0
NameRSVDRC_IERRRC_TXDISRC_SOFRC_BYTE _ERRRC_UNEXPRC_CRC
Reset00000000
RSVD =Reserved
RC_IERR =Detects initialization byte error in the received command frame. This may due to improper formatting of a byte such as a frame initialization byte is expected, but start-of-frame (SOF) bit is not set, or an invalid frame type is selected. Because bytes received on the COMH/COML are propagated up the stack, it is likely devices in the upper stack will also detect this error.
All bytes that follow are ignored until a SOF bit is set is received.
When a communication frame is ignored, the device will not attempt to detect any communication error in the ignored frame nor counting it as valid/discard in the frame counters.
0 = No error
1 = Error detected
RC_TXDIS =Valid when [DIR_SEL] = 1. Device detects the COMH TX is disabled but the device receives a command to read data (that is, to transmit data out). The command frame will be counted as a discard frame.
0 = No error
1 = Error detected
RC_SOF =Valid when [DIR_SEL] = 1. Detects a start-of-frame (SOF) error on COMH. The SOF bit is set only in the initialization frame but the SOF bit is set in the current frame that is not expected.
0 = No error
1 = Error detected
RC_BYTE_ERR =Valid when [DIR_SEL] = 1. Detected any byte error, other than the error in the initialization byte, in the received command frame. This error can trigger one or more error bit set in the DEBUG_COMMH_BIT register.
0 = No error
1 = Error detected
RC_UNEXP =If [DIR_SEL] = 0, but device receives command frame from COMH which is an invalid condition and device will set this error bit.
0 = No error
1 = Error detected
RC_CRC =Indicates a CRC error that resulted in one or more COMH command frames being discarded. Any other errors in the frame are not indicated as the frame was discarded.
0 = No error
1 = Error detected