8.1 Absolute Maximum Ratings(1)(2)
over operating free-air temperature range (unless otherwise noted) | MIN | MAX | UNIT |
| Supply voltage (with respect to PGND(3)) |
VBUS; VPMID ≥ VBUS –0.3 V |
–2 |
20 |
V |
| Input voltage (with respect to PGND(3)) |
SCL, SDA, OTG, SLRST, CSIN, CSOUT, CD |
–0.3 |
7 |
V |
| Output voltage (with respect to PGND(3)) |
PMID, STAT |
–0.3 |
20 |
V |
| VREF |
7 |
V |
| BOOT |
–0.7 |
20 |
V |
| SW |
–2(4) |
20 |
V |
| Voltage difference between CSIN and CSOUT inputs (V(CSIN) – V(CSOUT) ) |
±7 |
V |
| Voltage difference between BOOT and SW inputs (V(BOOT) – V(SW) ) |
-0.3 |
7 |
V |
| Voltage difference between VBUS and PMID inputs (V(VBUS) – V(PMID) ) |
–7 |
0.7 |
V |
| Voltage difference between PMID and SW inputs (V(PMID) – V(SW) ) |
–0.7 |
20 |
V |
| Output sink |
STAT |
10 |
mA |
| Output Current (average) |
SW |
1.55(2) |
A |
| TA |
Operating free-air temperature range |
–30 |
85 |
°C |
| TJ |
Junction temperature |
–40 |
125 |
°C |
| Tstg |
Storage temperature range |
–45 |
150 |
°C |
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltage values are with respect to the network ground terminal unless otherwise noted.
(2) Duty cycle for output current should be less than 50% for 10- year life time when output current is above 1.25A.
(3) All voltages are with respect to PGND if not specified. Currents are positive into, negative out of the specified terminal, if not specified. Consult Packaging Section of the data sheet for thermal limitations and considerations of packages.
(4) 20 ns duration